background image

LED PAR 19X10 Product Datasheet

 

LED PAR 19X10 Product Datasheet

 

05

 

06

 

 

 

 

 

 

Cautions: 

 

6.

 

INSTALLATIONS

 

7.

 

CONTROL CONNECTION

 

For added protection mount the fixtures in areas 
outside walking paths, seating areas, or in areas 
where the fixture might be reached by 
unauthorized personnel.

 

Before mounting the fixture to any surface, make sure 
that the installation area can hold a minimum point 
load of 10 times the 

device’s

 weight.

 

Fixture installation must always be secured with a 
secondary safety attachment, such as an appropriate 
safety cable.

 

Never stand directly below the device when mounting, 
removing, or servicing the fixture.

 

from a ceiling, or set on a flat level surface (see 
illustration below). Be sure this fixture is kept at least 
0.5m (1.5 f t) away from any flammable materials 
(decoration etc.).

 

Always use and install the supplied safety cable as a 
safety measure to prevent accidental damage and/or 
injury in the event the clamp fails.

 

 

Mounting  points: 

 

Overhead mounting requires extensive experience, 
including amongst others calculating working load 
limits, a  ne knowledge of the installation material 
being used, and periodic safety inspection of all 
installation material and the fixture. If you lack these 
qualifications, do not attempt the installation yourself. 
Improper installation can result in bodily injury.

 

Be sure to complete all rigging and installation 
procedures before connecting the main power cord to 
the appropriate wall outlet.

 

 

Clamp Mounting: 

 

The LED PAR 19X10 provides a unique mounting bracket 
assembly that integrates the bottom of the base, and 
the safety cable rigging point in one unit (see the 
illustration below). When mounting this fixture to truss 
be sure to secure an appropriately rated clamp to the 
included omega bracket using a M10 screw fitted 
through the center hole of the handle. As an added 
safety measure, be sure to attached at least one 
properly rated safety cable to the fixture using one of 
the safety cable rigging points integrated in the 
base assembly.

 

 
 

 
 

 
 

 

 
 

 
 

 

Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the 
male 3-pin XLR input of the moving head. You can chain multiple Moving head together through serial 
linking. The cable needed should be two core, screened cable with XLR input and output connectors.

 

Please refer to the diagram below. DMX-512 connection with DMX terminator.

 

For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, 
such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of 
the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a3 resistor 
connected between pins 2 and 3, which is then plugged into the output XLR socket of the last fixture in the 
chain. Please see illustrations below.

 

DMX IN 

DMX OUT

 

POWER OUT 

POWER IN

 

DMX512 OUT 

DMX512 IN

 

Signal (-)

 

1    2 

Signal (+) 

Ground  

3

 

120 

Ω

 

1

 

Signal (-)  

Signal (+)

 

DMX IN

 

POWER IN

 

 

 

Safety Clamp

 

 

 
 

 
 

 
 

 

Safety Cable

 

Содержание LUSTROUS-FX 1910

Страница 1: ...rsion 1 0 USER MANUAL Be sure to read the USER MANUAL carefully before using this product Be sure to keep the USER MANUAL properly for future needs Use this product correctly when you can fully understand the User Manual ...

Страница 2: ... device s housing bare hands during its operation housing becomes hot For replacement use lamps and fuses of same type and rating only It is absolutely essential that the fixture is kept clean and that dust dirt and smoke fluid residues must not build up onorwithinthefixture Otherwise thefixture slight outputwillbesignificantlyreduced Regular cleaning will not only ensure the maximum light output ...

Страница 3: ...and discos This manual covers the important information on installation and applications Meanwhile please keep this manual well for future needs 19 7 Macro Color 0 15 No Function 16 31 Red 32 47 Green 48 63 Blue 64 79 White 80 95 Red Green 96 111 Red Blue 112 127 Red White 128 143 Green Blue 144 159 Green White 160 175 Blue White 176 191 R G B 192 207 R G B W 208 212 2700K 213 217 3200K 218 222 35...

Страница 4: ...t temperature Mode Channel Value Function CH22 CH10 1 1 Dimmer 0 255 Dimmer 0 100 2 2 Shutter 0 31 Shutter closed 32 63 shutter open 64 95 Strobe effect slow to fast 96 127 shutter open 128 159 Pulse effect in sequences slow to fast 160 191 shutter open 192 223 Random strobe effect slow to fast 224 255 shutter open 3 3 Red 0 255 0 100 Red dimmer from dark to bright 4 4 Green 0 255 0 100 Green dimm...

Страница 5: ...cause electronic shock to the people Make sure the installation place is in good safety condition before installing the fixture Make sure to put the safety chain and check whether the screws are screwed properly when installing the fixture Make sure the lens is in good condition It s recommended to replace the units if there are any damages or severe scratch Make sure the fixture is operated by qu...

Страница 6: ...efore connecting the main power cord to the appropriate wall outlet Clamp Mounting The LED PAR 19X10 provides a unique mounting bracket assemblythatintegratesthebottomofthebase and the safety cable rigging point in one unit see the illustrationbelow When mounting thisfixturetotruss besuretosecureanappropriatelyrated clamptothe included omega bracket using a M10 screw fitted through the center hole...

Отзывы: