The universal tool is available to assist in the installation and service of the Bio-Kinetic system.  This device incorporates
a swab tool, locking lug tool, lifting tool and disassembly tool into one convenient package.  The swab tool simplifies the
application of Bio-Kinetic lubricant to the outlet components of the Singulair Green tank.  The locking lug tool engages and
disengages the locking lugs of the Bio-Kinetic system into the molded locking slots of the mounting riser.  The lifting tool
assists in the installation and removal of the Bio-Kinetic system from the Singulair Green tank.  The disassembly tool allows
the inner components of the Bio-Kinetic system to be removed and reinstalled without removing the entire assembly.

USING THE SWAB TOOL

The swab tool is used to apply Bio-Kinetic lubricant to the
rubber and plastic outlet connection components.  Proper
lubrication will insure the outlet connection engages easily
without leaks.  To prepare the swab tool for use, place a
clean cloth through the eyelet of the swab tool and apply
Bio-Kinetic lubricant to the cloth.

Examine the receiving flange in the outlet of the Singulair
Green tank.  The grooves and face of the receiving flange
should be free from debris.  Using the swab tool, apply a
liberal amount of Bio-Kinetic lubricant to the grooves and
face of the receiving flange.  Locate the gasketed discharge
flange assembly installed in the outlet of the Bio-Kinetic
system.  Remove any debris from the gasket with a clean
cloth.  Lubricate the gasket using the swab tool.

CAUTION:  Bio-Kinetic lubricant has been specially
formulated.  Use of other lubricants, especially
petroleum based lubricants, can cause degradation of
the rubber components and will void the warranty.

USING THE LOCKING LUG TOOL

The locking lug tool engages and disengages the locking
lugs into the molded locking slots of the mounting riser.
When locked into position, the locking lugs hold the
Bio-Kinetic system in place.  The locking lugs must be
disengaged to allow the Bio-Kinetic system to be removed
from the Singulair Green tank for service.

To engage or disengage the locking lugs, remove the
clarification chamber access cover and place it upside down
next to the mounting riser.  If the system is equipped with
Blue Crystal or Bio-Neutralizer feed tubes, carefully remove
each tube, one at a time.  Lay each feed tube on the inverted
access cover.  Do not allow the feed tubes to touch each
other.  Remove the service cover from the
Bio-Kinetic system.  Place the locking lug tool, located
opposite the fixed handle, over one of the locking lug bolts
of the Bio-Kinetic system.  Turn the locking lug tool
clockwise to engage or disengage lugs into the molded
locking slots of the mounting riser.

LUBRICATING THE OUTLET COMPONENTS

LOCKING DOWN THE BIO-KINETIC SYSTEM

SINGULAIR GREEN

®

 BIO-KINETIC

®

 WASTEWATER TREATMENT SYSTEM

USING THE UNIVERSAL TOOL