3/16”
#7
1/4-20
for Wood drill 7/32
Machine Screws
#7 Drill, 1/4-20 Tap
Thru Bolt and Grommet Nut
Drill 9/32 thru from Closer Side
3/8 Drill other Side
(Optional)
Metal
Wood
Installation Instructions
80-9380-2206-020 (04-09)
Non Hold Open Models
Sized
(Sizes 2,3,4,5,6)
8100
8300
8500
Adjustable
(Sizes 1 thru 6)
8301
8501
8000 Series Tri-Style
NOTE:
For special applications a separate
door and frame preparation template is
packed with these instructions. Use this
instruction sheet for installation sequence
and closer adjustments only.
Doors should be hung on ball bearing or
anti-friction hinges.
A separate door stop is recommended.
Door and frame must be properly
reinforced.
Always adjust spring power before
adjusting control.
Adjust closing time speed between 3 and 7
seconds from 90° to 0°. Greater closing
times may be required for elderly or
handicapped.
These door closers should NOT be
installed on the exposed side (weather
side) of exterior doors.
Left Hand Door - LH
Right Hand Reverse - RHR
Right Hand Door - RH
Left Hand Reverse - LHR
Right Hand Door - RH
Left Hand Reverse - LHR
Regular Arm
Installation
See Page 2
Left Hand Door - LH
Right Hand Reverse - RHR
Left Hand Door - LH
Right Hand Reverse - RHR
Top Jamb
Installation
See Page 5
Regular Arm
Installation
See Page 2
Parallel Arm
Installation
See Pages
3 & 4
Parallel Arm
Installation
See Pages
3 & 4
Optional 8500MA Series
Architectural
Metal Cover
Cover Screw
Cover Screws
Standoffs
Screw Pack
Optional 8500A Series
Architectural Plastic
Cover
Insert Cutouts
Cover
Insert
Standoff
Standoff
Cover Clips
Cover Screw
Cover Screws
Optional 8500M
Series
Metal Cover
Backcheck Valve
Power Adjustment Shaft
Latch Valve
Sweep Valve
Closer Body
Regular Arm/Top
Jamb Shoe
Connecting Rod
Forearm
Screw
Main Arm
Closer Arm
1618A Parallel
Arm Bracket
Cover
Insert
Standard 8500 Series
Full Cover
Insert Cutouts
Self Drilling Screws
Wood and Metal
For Wood drill 3/16 hole
Non Handed Door Closer
"DA" suffix (Delayed Action) is an optional
feature.
C
A
U
T
IO
N
C
A
U
T
IO
N
C
A
U
T
IO
N
C
A
U
T
IO
N
A n I n c o r r e c t l y i n s t a l l e d o r
improperly adjusted door closer can
cause property damage or personal
injury. These installation instructions
should be followed to avoid the
possibility of misapplication or
misadjustment.
!
NOTE:
Architectural Cover
CAN NOT be used for doors
swinging over 120° using
parallel mount
Standard 8300 Series
Narrow Cover
Pinion Cap (1639)
820
0P
Co
ver
840
0A
Co
ver
840
0P
Co
ver
84
00
M
A C
ov
er
840
0M
Co
ver
* Pilot Hole
Required
Top Jamb
Installation
See Page 5
Right Hand Door - RH
Left Hand Reverse - LHR