background image

7/32"

#7

1/4-20

Spring Power Adjustment Screw
1601(BF) Series Only

"BC" Valve

Pinion Cap

Closer
Size
Stamp

"L"Valve

"S"Valve

Standard Components

Optional Components

4

Closer Body

Co

ver

#14 Screws

for Wood drill 7/32

Machine Screws

#7 Drill, 1/4-20 Tap

Sleeve Nut and Bolt

Thru Bolt and Grommet Nut

Drill 9/32 thru from Closer Side

3/8 Drill other side

Drill 9/32 thru from Closer Side

3/8 Drill other Side

(Optional)

Metal

Wood

Top Jamb

Installation

See Page 5

1618A Soffit Plate
Used with Parallel

Arm Closers Only

Soffit Plate

CA

UTION

CA
UTION

An Incorrectly installed or improperly adjusted
door closer can cause property damage or
personal injury. These installation instructions
should be followed to avoid the possibility of
misapplication or misadjustment.

Installation Instructions

80-9316-2502-020 (10-08)

Non Hold Open Models

Sized

(Sizes 2,3,4,5,6)

1602BC
1603BC
1604BC
1605BC
1606BC

Adjustable

(Sizes 3 thru 6)

1601

(Sizes 1 thru 4)

1601BF

Non Handed Door Closer

Tri-Style

1600 Series

Regular Arm/Top

Jamb Shoe

Main Arm

Connecting Rod

Forearm
Screw

Arm Slide

Arm Assembly

1688

Plate

"DA" suffix (Delayed Action) is an optional

feature. A separate sheet is supplied

showing closer adjustments.

NOTE:

For special applications a separate

door and frame preparation template is
packed with these instructions. Use this
instruction sheet for installation sequence
and closer adjustments only.

Doors should be hung on ball bearing or
anti-friction hinges.

A separate door stop is recommended.

Door and frame must be properly
reinforced.

Adjust closing time speed between 3 and 7

These door closers should NOT be installed on the exposed side (weather side) of exterior doors.

Right Hand Door - RH
Left Hand Reverse - LHR

Left Hand Door - LH
Right Hand Reverse - RHR

Right Hand Door - RH
Left Hand Reverse - LHR

Right Hand Door - RH
Left Hand Reverse - LHR

Regular Arm

Installation

See Page 2

Left Hand Door - LH
Right Hand Reverse - RHR

Left Hand Door - LH
Right Hand Reverse - RHR

Top Jamb

Installation

See Page 5

Regular Arm

Installation

See Page 2

Parallel Arm

Installation

See Pages

3 & 4

Parallel Arm

Installation

See Pages

3 & 4

Weaker

-

Stronger

+

Содержание 1600 Series

Страница 1: ...ser Tri Style 1600 Series Regular Arm Top Jamb Shoe Main Arm Connecting Rod Forearm Screw Arm Slide Arm Assembly 1 6 8 8 P l a t e DA suffix Delayed Action is an optional feature A separate sheet is supplied showing closer adjustments NOTE For special applications a separate door and frame preparation template is packed with these instructions Use this instruction sheet for installation sequence a...

Страница 2: ...1 to 120 121 to 180 7 178 6 152 3 1 2 89 Dimension A Door Wall Hardware Jamb conditions permitting Right Hand Shown BC L S L S 1601 BF Only Spring Power Adjust If Necessary A B F 90 E D Inches mm 2 PA 2 or 1600 Series G Pinion Cap or Optional Cover Caution Don t completely close valve Optional Cover C L Y S Z R L S Stronger Weaker Slower Faster Faster Slower Stronger Weaker ...

Страница 3: ...235 7 3 4 197 5 3 4 146 B 7 5 8 194 6 1 8 156 4 1 8 105 C 8 5 8 219 7 1 8 181 5 1 8 130 2 3 4 70 3 8 10 1 2 13 7 16 11 2 50 A 1 1 2 38 7 178 4 102 2 1 8 54 3 1 4 83 1 2 13 3 4 19 9 1 16 230 C L C B Top of Door Door Wall Hardware Jamb conditions permitting Inches mm 5 3 S L Place Arm on Spindle Rotate Remove Arm from Spindle Close Valves L S Latch Sweep Optional Cover See Step 6 on Page 4 Frame Slo...

Страница 4: ... Adjust 1601 BF only If necessary PA BC S L S L 1 1 2 38 4 or 2 Assemble Arm Arm Screw Open Valves Caution Don t completely close valve Pinion Cap or Optional Cover L Y S Z R L Y S Z R Left Hand Door Right Hand Door or B A Flat Flat Slower Faster Weaker Stronger Stronger Weaker Slower Faster Caution Do Not Back Valve Out Completely ...

Страница 5: ...52 3 1 2 89 Dimension A Door Wall Hardware Jamb conditions permitting Right Hand Shown BC L S L S 1601 BF Only Spring Power Adjust If Necessary 90 Top of Door Inches mm 5 D B A E F PA G Parts Caution Don t completely close valve A longer connecting rod is required for reveals greater than 3 76 or Pinion Cap or Optional Cover Optional Cover Reveal C L Y S Z R Stronger Weaker Slower Faster Faster Sl...

Страница 6: ... 1 00M 44 1 10M 48 1 20M 1 1 2 3 3 2 2 3 4 5 5 6 8 8 9 12 2 4 6 9 11 3 5 7 10 13 3 5 7 10 13 5 7 10 14 16 NOT RECOMMENDED USE 1601 18 FULL 360 TURNS MAXIMUM AVAILABLE MAXIMUM DOOR SIZE Number of Turns Required Date Code or or 7 1 2 Stronger 7 1 2 Weaker Use 3 16 Hex Wrench for this Adjustment Use 1 8 Hex Wrench for these Adjustments Stronger Weaker Slower Faster Faster Slower Stronger Weaker 3 6 B...

Отзывы: