056341 Rev. AA
NAVIGAT X Mk 2
Page 2-10
2: Operation
2.10.2.2
Hdg. Diff. Alarm
Sets the parameters for the heading difference alarm function. If the difference
between the heading data from the monitored compasses exceeds the set
threshold, the heading difference alarm relay is actuated. Simultaneously, an
error message is displayed and an audible alarm given.
Between
Function:
Selects the heading sources to be monitored.
Settings: GY1/M
monitor internal gyro vs. magnetic heading
OFF
do not monitor heading difference
Diff.
Alarm
Function:
Enters the heading difference alarm threshold.
Settings:
0 – 99°
Note
The heading difference alarm function is not available if the system type is set
to G (Gyro only system).