background image

 

 

 

 

 

 

 

 

 

 

 

 

USE AND MAINTENANCE INSTRUCTIONS 

 

 

 

 

 

 

 

 

 
 

Carefully read the manual before  

installing and operating this gas heated water grill 

 
 
 

 

GAS WATER GRILL 

 

MODELS 

 

 Τ10  • Τ20 • T30 

 

 

      

 

 

 

0051 -  

SOTIRIOS D. PRODANAS & C.O. 

PROFESSIONAL ELECTRIC & GAS EQUIPMENT FOR RESTAURANTS – PATISSERIES – SNACK BARS 

NATIONAL ROAD KILKIS – THESSALONIKI. P.C.:61100 GALLIKOS KILKIS CROSSROADS – P.O. BOX: 40070. P.C 56404 

TEL : + 30 23410

 41991, 41819, - FAX: 

+ 30 23410

 41539 - email: info

@

north.gr – Http: //www.north.gr 

Содержание T10

Страница 1: ...ill GAS WATER GRILL MODELS Τ10 Τ20 T30 0051 SOTIRIOS D PRODANAS C O PROFESSIONAL ELECTRIC GAS EQUIPMENT FOR RESTAURANTS PATISSERIES SNACK BARS NATIONAL ROAD KILKIS THESSALONIKI P C 61100 GALLIKOS KILKIS CROSSROADS P O BOX 40070 P C 56404 TEL 30 23410 41991 41819 FAX 30 23410 41539 email info north gr Http www north gr ...

Страница 2: ...sure and nominal heat input controls 3 6 Adaptation to a different gas 3 6 1 Replacing the main nozzle and adjusting its primary air 3 6 2 Replacing the pilot nozzle and adjusting its primary air 3 6 3 Adjusting the minimum rate on gas valve through the by pass screw 3 7 Interventions repairs and replacements 4 INSTRUCTIONS FOR USING THE WATER GRILL for the user Page 10 4 1 Preliminary warnings be...

Страница 3: ... valid for the water grill described in this manual relevant to category II2H3 for Great Britain If the appliance is sold in a different European country with different category pressure and gases reported on the specifications data plate the manual shall be translated into the official language with the references gas connections and local installation regulations of that country Producer is resp...

Страница 4: ... 10226 1 e EN 10226 2 2 2 Technical data plates Gas category II2H3 Technical Data Unit T10 T20 T30 Normal thermal energy provide Kw 9 18 27 Consumption G30 G31 28 30 37 mbar Kg h 0 710 1 420 2 130 Consumption G20 20mbar m h 0 95 1 90 2 85 Main air regulation at G30 G31 28 30 37mbar mm 18 18 OPEN Main air regulation at G20 20mbar mm OPEN OPEN OPEN Main burner injector G30 28 30mbar G31 37mbar mm 15...

Страница 5: ...s vapours and steam from the cooking process According to national Regulations this gas heated water grill can be installed as an appliance of construction type For type A appliances the instructions shall state that these appliances are to be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room in which they are...

Страница 6: ...nd using leak finder sprays or other non corrosive foams do not use direct flames to look for leaks The burners are manufactured with a way to stand thermal and mechanical stress and are equipped with fixed nozzles This is why it is necessary to change the nozzles every time you change the type of gas Data concerning the appliance setting are to be found on the label on the backside of the applian...

Страница 7: ... the main nozzles the pilot nozzles adjust correctly the primary air of bush and then adjust the by pass screws on gas tapes to set the right rate at the reduced heat input Spare nozzles are provided with the appliance on its delivery or can be ordered near the seller Make sure that the diameter is printed on each nozzle in 1 100ths of a millimetre Only adapt the appliance after you have turned th...

Страница 8: ...s G30 G31 Then replace all the components in the reverse order 3 6 3 Adjusting the minimum rate on gas valve through the by pass screw The nozzle of the valve by pass screw has a hole of 1 10 mm Ø and for the gas G30 G31 must be fully screwed down Procced in the same way for each burner For the other gases G20 and G25 the by pass screw must be unscrewed for 1 complete round turning the screw anti ...

Страница 9: ... are operating property Explosions in the burners Check the pressure of the gas The pilot burner does not alight Ignition plug is faulty out of place or its electrical wire is disconnected Insufficient gas pressure Pilot nozzle is obstructed Gas tap is faulty The pilot burner flame does not keep alight Thermocouple is faulty it is not well licked up and heated by the pilot flame The main burner is...

Страница 10: ...water grill only to cook food Do not use it for different purposes because any other use is considered improper and dangerous Control the grill when operating Check the regular lighting of the main burner and verify the stability of the flames passing from the maximum to the minimum setting Blue color of flames is an indication of good combustion Before employing the grill for the first time clean...

Страница 11: ...r to undersign a contract of maintenance with technical personnel that foresees at least one full check up annually We specifically recommend regular checking to make sure the ignition source and the flame regulation are clean The gate valve must be checked at least once a year and if necessary restored the protection of specific oil If such an accurate observance of the contained instructions in ...

Страница 12: ...12 ...