Wave II Monitors
Specifications subject to changes without prior notice. The contents of
this page are property of North Invent Norway AS. All rights herein are
reserved to North lnvent Norway AS. This document cannot be
reproduced without the written permission of the company.
NORTH INVENT
Sørhauggata 128, NO-5527 Haugesund, Norway
Phone: + 47 48 84 02 00
[email protected] www.northinvent.com
6
7. Electrical Installation
All electrical connections are to be found on the lower back side of the Monitor. Necessary electrical indications are to be
found on the Terminal Plate at the bottom of the Monitor’s backside.
Figure: Terminal Plate for a full version Wave Monitor.
7.1. Pin-Assignments
AC Power
Pin
Description
Pin
Description
Pin
Description
N
Neutral
PE
Protective Earth
L
Line
The Monitor is connected to AC voltage by means of the standard AC power cable included in the delivery. The AC
current to the Monitor must be limited by a 3A fuse or similar.
DC Power
Pin
Description
Pin
Description
Pin
Description
1
Supply voltage, positive 18-36V
2
NC
3
Supply voltage negative
The Monitor is connected to DC voltage by means of the DC power plug included in the delivery and wires suitable for up
to 8 A. The Monitor will not be damaged by reversed polarity, may it occur.