9. SCOM support.
The monitor supports remote control by SCOM command on RS232 and RS485/422 interfaces as well as the LAN
interface (refer to 7.1 for pin assignments of the different connectors).
9.1. Interface parameters:
Parameter
Value
Baud rate
9.600
Parity
No
Data bits
8
Start bits
1
Stop bits
1
Handshake
No
9.2. Communication protocol:
The communication protocol complies with IEC 61162-1 (NMEA):
Byte 0
1
2 to 4
5
6
7 to LEN+6
LEN+7
ATT
ADR
CMD
LEN
IHC
DAT
IDC
The min message length is 7 bytes and the max message length is 82 bytes. The different bytes are described below.
Attention (ATT) byte:
This byte identifies the message start:
ATT
Description
0x07
Command
0x06
Acknowledge (OK)
0x15
Acknowledge (error)
Address (ADR) byte:
ADR
Description
0xFF
All controllers (0-15)
0x00
Controller 0
0x01
Controller 1
-
etc.
0x0F
Controller 15