Function
Setting
Description
Serial address of this monitor
1
– 254
Set the serial address of the monitor by utilizing the up and down
arrows.
The monitor will listen for and respond to SCOM commands on all
serial interfaces and the Ethernet interface only if a received
command matches this address or if the command is broadcast.
The monitor will not send a response to a broadcast command.
Serial I/F configuration
RS422
RS485
Configure the RS422 / 485 dual connector to either RS422 or
RS485 protocol by utilizing the dropdown menu.
Lock on serial comm
Checked
Not checked
By activating the checkbox the OSD cannot be activated if under
serial control.
When the checkbox is first checked, the operator will be presented
with a dialog that allows him to set a 4 digit pin code. Later, if the
operator tries to open the menu, he must input the same pin code
to do so.
This monitor is MultiDim master
Checked
Not checked
Activate checkbox to set monitor to MultiDim master.
This feature will allow an array of monitors to be dimmed and
controlled from a single monitor (the "MultiDim master"). When
changing the dimming level on the MultiDim master, the monitor
will also transmit a BRT broadcast command on the RS422/485
interface reflecting the new setting of the backlight level.
Relay keypresses to monitor
1
– 254
"Broadcast" checkbox:
Checked
Not checked
Set the serial address of another monitor on the same network in
order to remote control such monitor.
This feature allows the operator to relay the keypresses on a local
HMI to a remote monitor by RS485/422 to control it. Keypresses
are forwarded when the "broadcast " button is checked. To stop
relaying keypresses, the operator may uncheck the "broadcast"
button using a mouse or press and hold the ESC button for 5 sec.