Nortel NN42020-310 Скачать руководство пользователя страница 1

NN42020-310

Multimedia Communication Portfolio

Multimedia Communication Server

2-server Sun Fire V210 (RoHS) Solaris Installation and 
Commissioning Guide

MCS 5100 3.5  Standard  1.0  June 2006

Содержание NN42020-310

Страница 1: ...NN42020 310 Multimedia Communication Portfolio Multimedia Communication Server 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide MCS 5100 3 5 Standard 1 0 June 2006...

Страница 2: ......

Страница 3: ...ne hardware 25 Baseline hardware 25 Setting up rack to mount hardware 27 Connecting the Sun Fire V210 server to the layer 2 switch 28 Connecting the Sun Fire V210 server to the MRV LX terminal server...

Страница 4: ...and launching the System Management Console 97 Prerequisites 97 Installing the System Management Console 97 Launching the System Management Console 98 Adding a server 103 Prerequisites 103 Adding a se...

Страница 5: ...5 Installing and configuring the Oracle Monitor 141 Prerequisites 141 Procedures 141 Installing the iPlanet Monitor 149 Prerequisites 149 Procedures 149 Verification procedures 163 Verifying Server1 D...

Страница 6: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 6 Copyright Nortel Networks Limited 2006...

Страница 7: ...ates to the latest documentation and software for MCS 5100 click one of the following links Link to Takes you directly to the Latest Software Nortel page for MCS 5100 software located at www130 nortel...

Страница 8: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 8 Copyright Nortel Networks Limited 2006...

Страница 9: ...n download software documentation and product bulletins search the Technical Support Web site and the Nortel Knowledge Base for answers to technical issues sign up for automatic notification of new so...

Страница 10: ...can use an Express Routing Code ERC to quickly route your call to a specialist in your Nortel product or service To locate the ERC for your product or service go to www nortel com erc Getting help thr...

Страница 11: ...aximum of 250 subscribers This system allows more effective cost management for smaller sized enterprises This document describes the installation of the 2 server Sun Fire V210 Solaris system The 2 se...

Страница 12: ...at follows Print and refer to this example while executing this installation Print and complete the CSI datasheet with your own configuration to assist in executing this installation Configure the pc...

Страница 13: ...s a mirrored disk In the event of a disk failure the failed disk should be replaced as soon as possible The 2 server V210 Solaris system has the following limitations The system supports a maximum of...

Страница 14: ...5100 Provisioning Client User Guide NN42020 105 MCS 5100 H 323 Gatekeeper Basics NN10280 111 Media Application Server Network Engineering and Deployment Guide NN10377 191 MCS 5100 Ad Hoc Audio Confere...

Страница 15: ...re V210 RoHS Solaris Installation and Commissioning Guide 15 Copyright Nortel Networks Limited 2006 MCS 5100 Fault Management Alarm and Log reference NN10385 900 MCS 5100 Performance Management OM ref...

Страница 16: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 16 Copyright Nortel Networks Limited 2006...

Страница 17: ...Nortel Networks strongly recommends the use of high speed data network connectivity for optimum remote service capability Without broadband connectivity remote service options are limited Nortel Netw...

Страница 18: ...ing and no such activities are planned for the duration of the installation procedures and follow up soak period You have a detailed knowledge of your network s configuration You have proficiency usin...

Страница 19: ...mmands or buttons that you must press to perform an action for example Apply Courier type is used to signify what appears on screen for example Enter your password Italic type is used for emphasis for...

Страница 20: ...the same CDs on both servers at the same time to reduce installation time As shown in Table 2 Mapping of Kit NTVW01BD disks to servers with times Disks 1 5 have four copies each Disk 6 only needs to...

Страница 21: ...rder code NTVW01BD Approximatetime to install Server 1 Server 2 Management PC CD1 Disk Partitioning Solaris OS Kernel 45 minutes X X CD2 Solaris OS Packages 15 minutes X X CD3 Solaris Packages and Pat...

Страница 22: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 22 Copyright Nortel Networks Limited 2006...

Страница 23: ...e RAM minimum 64MB of RAM This requirement is in addition to the memory requirements of the operating system and other concurrent applications recommended 64MB of RAM This requirement is in addition t...

Страница 24: ...t applicable operating systems minimum Microsoft Windows 98 SE ME 2000 XP or Microsoft Windows NT 4 x with Service Pack 5 SP5 recommended Microsoft Windows 98 SE ME 2000 XP or Microsoft Windows NT 4 x...

Страница 25: ...See the following figure for an overview of the hardware connectivity Figure 3 Hardware connections overview ATTENTION You need an uninterrupted power source UPS If a power outage occurs bring the se...

Страница 26: ...SI disks second disk for mirroring CD ROM 2 10 100 Mbit Ethernet and USB Ports System configuration card Solaris 8 and ALOM v1 5 pre installed two 2 cat 5 Ethernet cables for each V210 server for a to...

Страница 27: ...server optional equipment Mount conference server Refer to the Media Application Server documentation for more information optional equipment Mount gateway Refer to customer specific gateway installat...

Страница 28: ...ure 4 MCS 5100 19 inch rack Connecting the Sun Fire V210 server to the layer 2 switch Procedure 2 Connecting the V210 server to the layer 2 switch At the back of the Sun Fire V210 server 1 Connect the...

Страница 29: ...to layer 2 switch Note 1 Net 0 and Net 1 are for redundancy It is preferable that each Ethernet port get cabled to a different layer 2 switch if available for maximum redundancy Note 2 The two Ethern...

Страница 30: ...server At the back of the Sun Fire V210 server 1 Connect the Sun Fire V210 server Net MGT LOM serial port and Serial MGT port to the MRV LX terminal server Figure 7 Sun Fire V210 server network callou...

Страница 31: ...ion and Commissioning Guide 31 Copyright Nortel Networks Limited 2006 Figure 8 P1 and P2 custom cable connections to terminal server See note Note This cable is only connected to configure the termina...

Страница 32: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 32 Copyright Nortel Networks Limited 2006...

Страница 33: ...l server is not needed and the cable can be removed 2 Connect the MRV terminal server 10 Base T port to the layer 2 switch Refer to the Getting Started with the LX 4000 Series document in the CD that...

Страница 34: ...t Nortel Networks Limited 2006 Figure 9 MRV Configuration Console window 2 Make sure you have the Java Plug in installed 3 When your browser connects to the terminal server the Java Security Warning w...

Страница 35: ...pted Console also require Java Runtime Environment 1 4 or later Choosing Not Encrypted Console means the GUI will run faster but without security Note The Java cache in JRE 1 4 is set to ON by default...

Страница 36: ...s Limited 2006 Figure 12 Login window 6 Enter your Username and Password and click Login Note By default authentication is done against the local user database To start use the known username InReach...

Страница 37: ...d 2006 Figure 13 User login window 8 To log in as a superuser click the Admin button on the tool bar and log in with the default Superuser password system You can now configure the unit at the GUI 9 C...

Страница 38: ...2006 Figure 14 Example selecting Ports Async a When you click on a port the following dialog box appears for you to enter your information Note In the TCP window see Figure 15 ensure that both the Te...

Страница 39: ...etworks Limited 2006 Figure 15 Port 19 dialog box For details on using the IP Configuration Menu refer to Using the IP Configuration Menu in the LX Series Configuration Guide For information on how to...

Страница 40: ...ized user knew this username password combination that user could log on to your unit For this reason you should change the user s password to something other than access The default Superuser passwor...

Страница 41: ...eruser password at the Re Enter your NEW password prompt The password will be displayed as asterisks Procedure 8 Accessing the MRV LX terminal server At the management pc 1 Select Start Programs Acces...

Страница 42: ...he command show ports 1 19 telnet chara Enter 13 Save your changes 14 Log out Note Using the command define saves the configuration 15 To kill a session on a port type logout port 12 Enter Procedure 9...

Страница 43: ...400 physical ports 11 14 The port number identifies the location of the target host This value is based on the following formula 2000 Port number physically connected on the MRV LX terminal server x 1...

Страница 44: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 44 Copyright Nortel Networks Limited 2006...

Страница 45: ...servers will more than likely boot up to a Solaris System Identification screen Do not answer those questions Send a break to get to the ok prompt so you can then boot from the CD ROM Procedure 11 Pow...

Страница 46: ...5100 3 5 Standard 1 0 June 2006 46 Copyright Nortel Networks Limited 2006 4 The ok prompt appears ATTENTION If you do not use PuTTY use the appropriate key sequence to send a break to the server to g...

Страница 47: ...nd new machine connect through the terminal server to the Net MGT LOM port until after you have installed CD5 Then log out Log back in through the terminal server to Serial MGT port for the rest of th...

Страница 48: ...or English 0 Enter What type of terminal are you using 6 Select three 3 for DEC VT100 3 Enter Note The following message is displayed The system is coming up Please wait Solaris Installation Program P...

Страница 49: ...for example micromgmt Note 1 Host name cannot start with a number Host names must be at least two characters and can contain alphanumeric characters and minus signs Note 2 Host names must be unique w...

Страница 50: ...orrectly Press Esc 2 to continue Press Esc 4 if you need to change anything Configure Security Policy 12 Confirm the Kerberos information by accepting the default No Press Esc 2 to continue Confirm in...

Страница 51: ...eys to navigate to the required time zone and press the spacebar to mark your choice Press Esc 2 to continue Please wait for the next prompt 18 At the Date and time prompt set up the date and time Pre...

Страница 52: ...ch one 2 You will then see the following message What type of installation are you performing 1 Typical 2 CustomType 1 and press Enter 3 You will then see the following message Ready to Install Instal...

Страница 53: ...ROM drive and press Enter at the prompt The installation will continue Please wait The system will prompt you for the next step 2 Log in as root Enter 3 Enter your customer specific password Enter Not...

Страница 54: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 54 Copyright Nortel Networks Limited 2006...

Страница 55: ...Management and Accounting service will be the source You will need to provide the Machine Logical IP Address of each server If running simplex mode provide the same address twice 2 Press Enter to con...

Страница 56: ...rce you will be prompted as follows How many external clock sources would you like to reference 1 Enter 1 You will then see the following message External Clock Source IP Address 1 Enter your clock so...

Страница 57: ...physical IP address for the bge0 interface Physical IP address of the bge0 interface Enter Example 120 120 13 20 12 Enter the secondary machine physical IP address for the bge1 interface Physical IP a...

Страница 58: ...will come up as shown in the following figure Figure 16 Database Management Accounting server IPMP configuration summary Is this IPMP group configuration acceptable Y N Select Y and press Enter 15 The...

Страница 59: ...entered the following IP addresses Machine Logical IP Address of the other MgmtSvr 120 120 13 22 Service Logical IP Address of SysMgr 120 120 13 22 Service Logical IP Address of AcctMgr 120 120 13 22...

Страница 60: ...proximate time estimate 15 minutes Procedure 16 Installing CD4 At the management pc 1 Place CD4 in the CD ROM drive and press Enter to continue WAIT until you see the following statement appear You ar...

Страница 61: ...e IP multipathing configuration for Sun Solaris information appear press Enter to accept it or type in a preferred setting The default failover timeout is set to 1000mSec 9 Enter the primary machine p...

Страница 62: ...list is complete if entering less than six targets Note Do NOT use this server s own IP address as a ping target 12 Press Enter after each IP address for example 0 0 0 0 Enter This is the third ping t...

Страница 63: ...ill need to enter the following information IP address for the Physical Ethernet Net Management port Netmask for the Physical Ethernet New Management port Gateway IP address Note If the Net Management...

Страница 64: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 64 Copyright Nortel Networks Limited 2006...

Страница 65: ...mtSvr AcctMgr only on page 69 for instructions The Application IPCM server AppSvr IPCM will reboot 2 After the AppSvr IPCM reboot log into this server using the Serial MGT port and change the password...

Страница 66: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 66 Copyright Nortel Networks Limited 2006...

Страница 67: ...edure 18 Enabling or disabling the CD ROM auto mount At the management pc 1 The system disables volmgt by default after CD5 is installed To toggle it back on to install additional CDs follow this step...

Страница 68: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 68 Copyright Nortel Networks Limited 2006...

Страница 69: ...gement pc 1 Place CD6 in the CD ROM drive on the server and press Enter at the prompt Note CD6 will eject from the CD ROM when installed 2 After the reboot log in using the Serial MGT port and change...

Страница 70: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 70 Copyright Nortel Networks Limited 2006...

Страница 71: ...vr At the management pc 1 Use PuTTY to connect to the database server using Serial MGT port which connects to the LX terminal server 2 Log in as root to the Management Accounting server 3 Enter your c...

Страница 72: ...empty This allows for easy removal of files later 11 Please insert Oracle Disks 2 6 into the CD ROM drive Enter Note You will receive the following prompts for each CD entered Copying files from CDROM...

Страница 73: ...cept the default N Enter 17 You will then see a confirmation screen If the information on the screen is correct type Y Otherwise type N and make the changes Note At this point the program runs a check...

Страница 74: ...ng Disk 1 Disk2 Disk3 Disk4 Disk5 Disk6 from IMS ora_cds Oracle_Install Complete 20 At the completion of the script you will see the message Oracle_Install complete Press Ctrl C to exit 21 To check fo...

Страница 75: ...schemas and configurations Commands are executed on each server using PuTTY SSH into the machine logical IP address ex 120 120 13 25 The procedure to install the database load for the first time is c...

Страница 76: ...Enter the machine logical IP address of the MgmtSvr or press Enter to accept default Example 120 120 13 22 8 Enter the Service Logical IP address of the SysMgr Enter the service logical IP address of...

Страница 77: ...al IP address of the management server At the UNIX prompt the operator the uses the script mgmtdeploy pl to deploy and start the Sysmgr This process is described in the following section Deploying and...

Страница 78: ...Please enter the number 1 of the load to deploy 1 4 Is the database replicated N Enter 5 Enter Machine Logical IP Address Primary DB machine logical IP address of the database server Example 120 120 1...

Страница 79: ...information Notice that the script waits 30 seconds between process executions The script is starting three processes that must be running in order to continue MCS load deployment The three processes...

Страница 80: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 80 Copyright Nortel Networks Limited 2006...

Страница 81: ...e Retrieval System webpage The site will normally consist of one or two Management and Accounting servers this set is called the CORE and one or more Media Application Servers MAS Each server has two...

Страница 82: ...ation select a login server that matches your region for example European Login or North American Login 5 In step 2 Product Family select the product you wish to generate keycodes for in this case sel...

Страница 83: ...V210 RoHS Solaris Installation and Commissioning Guide 83 Copyright Nortel Networks Limited 2006 Figure 19 Keycode Retrieval System Creating your site 7 Select Create to register a new system The fol...

Страница 84: ...Limited 2006 Figure 20 Keycode Retrieval System Entering your site information 8 Fill in the requested information and press the Continue button Ensure you choose the correct software version from th...

Страница 85: ...ommissioning Guide 85 Copyright Nortel Networks Limited 2006 Figure 21 Keycode Retrieval System Current Summary 9 Select the server you want to enter MAC addresses for first then click on Create 10 En...

Страница 86: ...in If you have a second Core that is going to be installed as a redundant server enter all four MAC addresses at this time 12 When finished you will need to select Create again to enter the Media Appl...

Страница 87: ...cond Media Application Server for your system you must select Create a second time as only two MAC addresses can be associated with any one Media Application Server Figure 23 Keycode Retrieval System...

Страница 88: ...ard 1 0 June 2006 88 Copyright Nortel Networks Limited 2006 Figure 24 Keycode Retrieval System Current Summary 15 To generate keycodes for this site click on Gen KC with Auth Code from the side bar as...

Страница 89: ...e Retrieval System Gen KC with Auth Code 16 To generate your keycodes enter one of the MAC addresses of the server you want your Auth code applied to In this case the example shows one of the CORE MAC...

Страница 90: ...MCS 5100 3 5 Standard 1 0 June 2006 90 Copyright Nortel Networks Limited 2006 Figure 26 Keycode Retrieval System Finding the keycode 18 Select the proper Software Version for your system Then click o...

Страница 91: ...ioning Guide 91 Copyright Nortel Networks Limited 2006 Figure 27 Keycode Retrieval System Adding a MAC address 19 Enter the authcode number for the feature you wish to enable into the Auth Code box Us...

Страница 92: ...r server type CORE or MAS If validated successfully you will be allowed to enter more authcodes until you ve entered all for your server When this process is complete click on Continue 22 The followin...

Страница 93: ...features 23 The KRS will indicate it is generating your keycodes and saving the results in its database After generating the keycodes and saving results in the KRS database the system shows the Retri...

Страница 94: ...screens show the features of your keycode and the option to download the keycode to your local PC To download the keycode click on Download Keycode From there you will see the screens to download the...

Страница 95: ...10 RoHS Solaris Installation and Commissioning Guide 95 Copyright Nortel Networks Limited 2006 Figure 31 Keycode Retrieval System Retrieving your keycode part 2 24 Download the new license key file to...

Страница 96: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 96 Copyright Nortel Networks Limited 2006...

Страница 97: ...ocedure 25 Installing the System Management Console At the management pc 1 Put the MCS Base Platform System Software CD MCS Management Console PC software into the PC s CD ROM 2 Navigate to the CD ROM...

Страница 98: ...ialize the whole network view it will take up to a minute for the system manager screen to appear The default base directory where the System Management Console is installed on the management pc is C...

Страница 99: ...stem License Key Update menu option from the System tree as shown in Figure 32 Management Console Update License Key The System item on the file tree must be highlighted Figure 32 Management Console U...

Страница 100: ...nse key file by highlighting the file and pressing Apply Once the file is selected the license key appears in the text area If a wrong file is selected the Open File button can be used to select a dif...

Страница 101: ...l Networks Limited 2006 The console screen has the basic look and feel of a Windows Explorer window with a tree structure on the left and a general information area on the right Each folder on the man...

Страница 102: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 102 Copyright Nortel Networks Limited 2006...

Страница 103: ...r Procedure 27 Adding a server At the System Management Console 1 Select Sites MgmtSite Servers 2 Right click on the Servers folder 3 Select Add General 4 Use the following system server fields to com...

Страница 104: ...IP address of the server 120 120 13 25 Snmp Port Request Leave the default value as is default Polling interval 240 default Terminal Server Type Drop down menu with the following choices MicroAnnexTer...

Страница 105: ...CS 5100 Procedures Procedure 28 Adding an Accounting Module component to the server At the System Management Console 1 Select Sites MgmtSite Servers Add General MgmtSvr See Adding a server on page 103...

Страница 106: ...parameters Note The shaded row indicates values that must be addressed by the installer Table 1 Central Accounting Manager tab Sheet 1 of 2 Parameter Recommended value Notes Example CAM IP Address ma...

Страница 107: ...Application Modules and Accounting Module default TCP IP Address 0 0 0 0 default TCP IP Primary Host Port 9000 default TCP IP Recovery Host Port 9001 default FTP Push Enabled unchecked default Primar...

Страница 108: ...S 5100 3 5 Standard 1 0 June 2006 108 Copyright Nortel Networks Limited 2006 The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in...

Страница 109: ...Site Servers Add General AppSvr See Adding a server on page 103 for information on how to add a server before adding the SIP Application Module 2 Click on the plus sign next to the server to which you...

Страница 110: ...Notes Example Authorized SIP Nodes IP addresses of other trusted application servers conference servers and gateways this application module interacts with A trusted relationship implies that this en...

Страница 111: ...henticated subscribe Presence authenticated message Instant Message authenticated Table 2 Authentication tab Sheet 2 of 2 Parameter Recommended value Notes Example Table 3 Local Accounting Manager tab...

Страница 112: ...ter into the Database Base tab parameters Disk Monitor Critical Threshold 75 default Enable Billing For Instant Message unchecked default Table 3 Local Accounting Manager tab Sheet 2 of 2 Parameter Re...

Страница 113: ...ue Notes Example Primary Host machine logical IP of database server 120 120 13 22 Connections 8 default Secondary Host Not applicable Table 7 SIP TCF Base tab Parameter Recommended value Notes Example...

Страница 114: ...t Update interval for domain information 600 default Number of users 2000 default Update interval for presence limits 86400 default Update interval for admin banned users 900 default Update interval f...

Страница 115: ...from the table that follows to complete the Long Call Service tab parameters 13 Use the values from the following table to enter into the Server Properties tab parameters Table 10 Registrar Service t...

Страница 116: ...pplication server This value is for the Public_Service_Address 120 120 13 25 Service Parameter Label Private_Service_Address not applicable default Value leave blank default Service Parameter Label Ca...

Страница 117: ...se queue high threshold 40 40 Database queue low threshold 1 default Protocols Monitored sip default Table 15 Overload Controls tab Continued Parameter Recommended value Notes Example Table 16 Transpo...

Страница 118: ...NSD Enabled unchecked Box unchecked NSD Enabled Label Public_Service_Address default Value service logical IP address of NSD1 Parameters Service Parameter Transport Enabled checked Check the first tw...

Страница 119: ...the file tree Parameters Service Parameter Transport Enabled checked Check the first two Transport Enabled boxes for UDP and TCP that display Uncheck all subsequent instances of Transport Enabled Prot...

Страница 120: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 120 Copyright Nortel Networks Limited 2006...

Страница 121: ...es MgmtSite Servers Add General AppSvr See Adding a server on page 103 for information on how to add a server before adding the AppSvr 2 Click on the plus sign next to the server to which you are addi...

Страница 122: ...able 17 IP Client Manager tab Sheet 1 of 2 Parameter Recommended Value Notes Example VM Client Contact voicemail default Cluster Name customer specified IPCM cluster name ipcmCluster IP Address machin...

Страница 123: ...irmware ID D61 default Use UFTP checked Box is checked default UFTP Server Port 50020 default Keep Alive Timer 40 default KA Phone Timer 90 default Switch Server Delay 5000 default Min ReReg Delay 600...

Страница 124: ...Parameter Recommended value Notes Example LocalHost machine logical IP address of the IPCM server 120 120 13 25 Port 5000 default Table 20 SIP TCF Base tab Parameter Recommended value Notes Example T...

Страница 125: ...k Apply The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree Table 22 In Memory Database tab Parameter Recommended...

Страница 126: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 126 Copyright Nortel Networks Limited 2006...

Страница 127: ...the IPCM for firmware Add the UFTP to the System Management Console Procedure 34 Adding the UFTP software At the System Management Console 1 Select Sites MgmtSite AppSvr 2 Click on the plus sign next...

Страница 128: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 128 Copyright Nortel Networks Limited 2006...

Страница 129: ...o the server to which you are adding the component 3 Right click on the Components folder 4 Select Add Component 5 A list of component loads appears in the Load List window Select the latest load for...

Страница 130: ...4 SIP TCF Base tab Parameter Recommended value Notes Example Transport Config UDP machine logical IP of IPCM Server 5070 optional TCP machine logical IP of IPCM Server 5070 optional Replace each insta...

Страница 131: ...ked default Ping Time Out Timer 60 default Ping Interval Timer 120 default Connection Time Out Timer 360 default Allow Auto Login checked default Download JRE Version This field holds the version of t...

Страница 132: ...at must be addressed by the installer Table 27 Database Base tab Parameter Recommended value Notes Example Primary Host machine logical IP database server 120 120 13 22 Connections 8 default Secondary...

Страница 133: ...he Conference_Service tab parameters 8 Click Apply Note A progress window will display indicating the status of the deployment The component will deploy Wait until you see the dialog box indicating su...

Страница 134: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 134 Copyright Nortel Networks Limited 2006...

Страница 135: ...icro At the System Management Console 1 Select Sites MgmtSite Servers AppSvr 2 Click on the plus sign next to the server to which you are adding the component 3 Right click on the Components folder 4...

Страница 136: ...shaded rows indicate values that must be addressed by the installer 2 Use the values from the table that follows to complete the SIP TCF Base tab parameters ATTENTION Do not click Apply until you have...

Страница 137: ...e WCM Server 5085 optiona l name sipLscConduit TCP machine logical IP of the WCM Server 5085 optiona l name sipLscConduit Replace each instance of 0 0 0 0 in the UDP and TCF strings with the machine l...

Страница 138: ...taller that the Web Client applet downloads For the latest version of the installer from Sun leave this field empty For the installer provided by the MCS The MCS currently provides 5 different JRE ins...

Страница 139: ...dressed by the installer 6 Click Apply 7 The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree Table 35 Database Bas...

Страница 140: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 140 Copyright Nortel Networks Limited 2006...

Страница 141: ...em Management Console At the System Management Console 1 Select Sites MgmtSite Servers MgmtSvr 2 Click on the plus sign next to the server to which you are adding the component 3 Right click on the Co...

Страница 142: ...N Do not click Apply until you have finished configuring the component Table 36 Oracle Server tab Parameter Recommended value Notes Example SNMP request port 9161 default SNMP agent IP address either...

Страница 143: ...e Monitor is running on 120 120 13 22 Oracle Server name imsdb1 default Oracle Database name imsdb1 default Active checked default Component name TableSpace default Polling interval min 1 default Acti...

Страница 144: ...efault Gauged Component Monitoring Threshold monitors Positive going threshold hysteresis 2 5 default Gauged Component Monitoring Threshold monitors Capacity or max value 99 default Gauged Component M...

Страница 145: ...Gauged Component Monitoring Threshold monitors Alarm Severity on Lower Limit underrun MAJOR default Gauged Component Monitoring Threshold monitors Usage state affected unchecked default Monitor funct...

Страница 146: ...val min 1 default Monitor functions Active checked default Monitor functions Component name CacheHitRatio default Monitor functions Polling interval min 1 default Monitor functions Active checked defa...

Страница 147: ...essful installation The component will appear in the file tree Table 39 Oracle Listeners tab Parameter Recommended value Notes Example SNMP request port 9161 default SNMP agent IP address either the w...

Страница 148: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 148 Copyright Nortel Networks Limited 2006...

Страница 149: ...MgmtSite Servers AppSvr 2 Click on the plus sign next to the server to which you are adding the component 3 Right click on the Components folder 4 Select Add Component 5 A list of component loads appe...

Страница 150: ...tor tab Sheet 1 of 12 Parameter Recommended value Notes Example SNMP request port 8161 default SNMP agent IP address machine logical IP of Provisioning Module 120 120 13 25 Active checked default Comp...

Страница 151: ...nitoring Threshold monitors Positive going threshold value 1 70 default Component Monitoring Threshold monitors Positive going threshold hysteresis 1 5 default Component Monitoring Threshold monitors...

Страница 152: ...ld monitors Alarm Severity on Maximum Rate MAJOR default Component Monitoring Threshold monitors Alarm Severity on Upper Limit OverRun MAJOR default Component Monitoring Threshold monitors Alarm Sever...

Страница 153: ...nt Monitoring Threshold monitors Positive going threshold hysteresis 1 5 default Component Monitoring Threshold monitors Positive going threshold value 2 85 default Component Monitoring Threshold moni...

Страница 154: ...m Severity on Upper Limit OverRun MAJOR default Component Monitoring Threshold monitors Alarm Severity on Lower Limit OverRun MAJOR default Component Monitoring Threshold monitors Usage state affected...

Страница 155: ...value 99 default Component Monitoring Capacity or max hysteresis 0 default Alarm Severity on Negative going threshold NONE default Alarm Severity on Positive going threshold 1 WARNING default Alarm Se...

Страница 156: ...t 100 default Component Monitoring Threshold monitors Lower Limit 0 default Component Monitoring Threshold monitors Negative going threshold value 10 default Component Monitoring Threshold monitors Ne...

Страница 157: ...m Severity on Negative going threshold NONE default Component Monitoring Threshold monitors Alarm Severity on Positive going threshold 1 WARNING default Component Monitoring Threshold monitors Alarm S...

Страница 158: ...Component Monitoring Active for polling checked default Component Monitoring Threshold monitors Gauge name percentThreadPoolUs age default Component Monitoring Threshold monitors Upper limit 100 defa...

Страница 159: ...ring Threshold monitors Capacity or max value 99 default Component Monitoring Threshold monitors Capacity or max hysteresis 0 default Component Monitoring Threshold monitors Alarm Severity on Negative...

Страница 160: ...t Component Monitoring Component name Web Server Stats default Component Monitoring Polling interval in minutes 1 default Component Monitoring Active for polling checked default Component Monitoring C...

Страница 161: ...Click Apply Wait for the component to appear in server list The iPlanet Monitor is installed on the same server as the Provisioning Module Trap handlers Trap handler name iPlanet Operation Trap defau...

Страница 162: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 162 Copyright Nortel Networks Limited 2006...

Страница 163: ...to verify IP addressing mcsmicromgmt export home nortel ifconfig a lo0 flags 1000849 UP LOOPBACK RUNNING MULTICAST IPv4 mtu 8232 index 1 inet 127 0 0 1 netmask ff000000 bge0 flags 9040843 UP BROADCAST...

Страница 164: ...ways attempt to attach to the first interface bge0 If bge0 were unavailable or out of service the machine logical would then attach itself to bge1 creating bge1 1 The parameters which follow show the...

Страница 165: ...dressing mcsmicroapp export home nortel ifconfig a lo0 flags 1000849 UP LOOPBACK RUNNING MULTICAST IPv4 mtu 8232 index 1 inet 127 0 0 1 netmask ff000000 bge0 flags 9040843 UP BROADCAST RUNNING MULTICA...

Страница 166: ...machine logical would then attach itself to bge1 creating bge1 1 The parameters that follow show the IP address subnet mask and whether the interface is UP This example output shows that bge0 1 is ass...

Страница 167: ...logical IP address Example Open a PuTTY SSH session to 120 120 13 22 Procedure 45 Verifying the database load imssipdb deployment At the management pc 1 Log into the database server as nortel new nor...

Страница 168: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 168 Copyright Nortel Networks Limited 2006...

Страница 169: ...in Winzip should be checked 2 Identify the Provisioning Module server s on which to deploy the load 3 Customization of the JNLP file pcclient jnlp is possible by modifying certain attributes For exam...

Страница 170: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 170 Copyright Nortel Networks Limited 2006...

Страница 171: ...is system identification process and then invokes the MCP commissioning script at root login This is the same configuration procedure executed during CD installation and commissioning and is common fo...

Страница 172: ...warning message This program will unconfigure your system It will cause it to revert to a blank system It will not have a name or know about other systems or networks This program will also halt the...

Страница 173: ...iPV6 Confirm Security Policy Confirm Note This procedure skips some of the steps for initial installation of CD1 Regions Time Zone Date Time Confirm Password You will then see System identification is...

Страница 174: ...NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 174 Copyright Nortel Networks Limited 2006...

Страница 175: ......

Страница 176: ...ment are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this documen...

Отзывы: