background image

Page 7 of 18

Message Registration

Description and operation

12

Description

Message Registration (MR) is an optional software package that meters local 
calls over designated central office (CO) trunks. The Message Registration 
(MR) feature counts Reverse Battery (RVB) pulses from outgoing loop start 
or ground start CO trunks. Pulses received are stored in software meters. Each 
meter is assigned to a Directory Number (DN) or trunk access code that 
requires metering.

The Message Registration feature allows each customer within the system to 
keep an accurate record of CO calls for billing and administration purposes.

— Each Directory Number (DN) of three or more digits, including the 

attendant DN, can be assigned a software meter. For multiple appearance 
DNs, only one meter is assigned to meter all calls to the Prime DN 
(PDN). Stations with multiple DN keys have a meter allocated for each 
DN key.

— Meters can also be assigned to tie trunk routes. A tie route meter can be 

assigned to the route access code of each tie route in the customer group. 
An access code for a metered route must be at least three digits long.

— The system automatically assigns one customer meter for each customer 

within the system. This customer meter is used to store pulses that cannot 
be added to particular DN or trunk meters assigned in the customer 
group.

Software meters are assigned in LDs 10 and 11. Each meter number 
corresponds to the DN or trunk access code to which it is assigned. Meters 
can be either ON or OFF. When a meter is turned off, pulses received are not 
stored. The customer meter is always on and cannot be turned off. Meters can 
also be turned on or off individually or in groups, using a background 
terminal (BGD).

Содержание Message Registration

Страница 1: ...the limits for a Class A digital device pursuant to Part 15 of the FCC rules and the radio interference regulations of Industry Canada These limits are designed to provide reasonable protection agains...

Страница 2: ......

Страница 3: ...ardware and software described is supported in your area December 1994 Standard release 3 00 Reissued to include editorial changes and indexing Due to the extent of the changes revision bars are not u...

Страница 4: ...Page 4 of 18 Revision History 553 2701 101 Standard 4 00 April 2000...

Страница 5: ...ion Contents Description 7 Feature interactions 9 Operating parameters 10 Feature administration 10 Hardware description 10 Trunk circuit cards 10 Reverse Battery operation 11 Operation 13 Background...

Страница 6: ...Page 6 of 18 Contents 553 2701 101 Standard 4 00 April 2000...

Страница 7: ...only one meter is assigned to meter all calls to the Prime DN PDN Stations with multiple DN keys have a meter allocated for each DN key Meters can also be assigned to tie trunk routes A tie route met...

Страница 8: ...appears as follows CUST MTR xx OVF 32766 When equipped with the MR feature the system is capable of the following provisions Attendants are able to meter outgoing local calls over CO routes Meter con...

Страница 9: ...is transferred to a station that is forwarded to another internal station Conference Only the party originating the Conference Call is metered Trunk to trunk calls Metering of trunk to trunk calls us...

Страница 10: ...lared as metered or nonmetered in LD16 trunk route data block Calls should not be allowed to overflow from metered to nonmetered routes A software meter must be assigned in the Customer Numbering Plan...

Страница 11: ...and pad settings Reverse Battery operation When the CO trunk returns a Reverse Battery RVB signal only one pulse is received for each outgoing call This pulse is passed to the software meter for stor...

Страница 12: ...Page 12 of 18 Description 553 2701 101 Standard 4 00 April 2000...

Страница 13: ...For a complete and detailed description of all the BGD commands refer to the Background Terminal Facility description 553 2311 316 The general command format for the BGD appears as follows SEt OPtion...

Страница 14: ...9 SE ME 1246 VA 9 If the global COnfirm command is switched on the following response appears if the meter had previously been switched off ME 1246 OFF TO 9 Enter the following command to set meter 1...

Страница 15: ...1249 to a value of 9 using the X substitution method SE ME 124X VA 9 Enter the following command to set all meters to a value of 9 SE ME AL VA 9 Table 2 summarizes the MR set commands Access to meter...

Страница 16: ...e customer s meter is allowed from the BGD only Table 2 MR set commands Command line AU hhmm PR MEter dn VAlue nnnnn SEt command only FInd dn1 dn2 ZEro SEt dnX ON port ID ALl OFf CUstomer DIsplay ON O...

Страница 17: ...Coordinated Dialing Plan 10 command summary BGD 13 MR set 16 Conference Calls 9 COS class of service 8 customer meter accessing 16 commands accessing 15 ON OFF state 7 overflow message 8 D DN Director...

Страница 18: ...rs 10 operation 13 P pulses See RVB Reverse Battery pulses R RMS room status information 15 room phones 8 RVB Reverse Battery pulses counting 7 operation 11 S selecting Multiple Appearance DNs 15 sing...

Страница 19: ......

Страница 20: ...FCC rules and the radio interference regulations of Industry Canada These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commerc...

Отзывы: