330
MCRM-S card replacement procedures
555-4031-547 Standard 12.02 July 2002
NTMX87
in an MCRM-S EXT or RCC2 shelf
(continued)
10
Use the following information to determine where to proceed.
11
Busy the inactive PM unit by typing the following string:
> bsy unit rcc2_unit_no
and pressing the Enter key.
where
rcc2_unit_no
is the number of the inactive RCC2 unit (0 or 1)
12
Post the host PM by typing the following string:
>POST host_pm host_pm_no
and pressing the Enter key.
Allow 15 minutes for messaging to clear between the CC and the
RCC2.
where
LINK 0
RCC2 0
5
27;CAP
MS:STATUS OK
MSGCOND
OPN
LINK 1
RCC2 1
5
27;CAP
MS:STATUS SBsy MSGCOND
CLS
LINK 2
RCC2 0
7
47;CAP
MS:STATUS OK
LINK 3
RCC2 1
7
47;CAP
MS:STATUS OK
LINK 4
RCC2 0
5
50;CAP
MS:STATUS OK
MSGCOND
OPN
LINK 5
RCC2 1
5
50;CAP
MS:STATUS SBsy MSGCOND
CLS
If P-side links are
Do
faulty
Step 13
not faulty
Step 33
Содержание Meridian SL-100 SE
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history 555 4031 547 Standard 12 02 July 2002...
Страница 10: ...x Contents 555 4031 547 Standard 12 02 July 2002...
Страница 46: ...46 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 56: ...56 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 72: ...72 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 80: ...80 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 96: ...96 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 108: ...108 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 120: ...120 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 138: ...138 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 149: ...149 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 150: ...150 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 160: ...160 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 187: ...187 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 188: ...188 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 198: ...198 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 208: ...208 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 218: ...218 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 228: ...228 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 252: ...252 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 294: ...294 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 320: ...320 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 322: ...322 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Страница 337: ......