Chapter 15 – Installing and connecting SDI and Ethernet ports
Page 129 of 536
Option 11C Compact
Planning, Installation, Fault Clearing and CCBR Guide
Procedure 14
Connecting SDI ports on the SSC card
1
Connect the NTBK48 3-port SDI cable to the 9-pin SDI connection
at the bottom of the main cabinet.
Figure 31
Cable connection
2
Connect the system terminal to the cable marked “port 0” on the
NTBK48 3-port cable.
A Modem Eliminator Adapter is required to connect the Option 11C
Compact system to a TTY terminal.
3
If the system is to be accessed remotely, connect the system
modem to the cable marked “port 1” on the NTBK48 cable.
4
Connect the modem to an outside line.
5
Test the modem for proper operation once the system is
operating.
Note: The remaining ports can be used for other equipment such as
CDR devices or TTYs.
—————————— End of Procedure ——————————
NTBK48 cable connection
Содержание Meridian Meridian 1
Страница 3: ...553 3121 210 Standard 3 0 January 1999 ...
Страница 17: ...xiv Contents 553 3121 210 Standard 3 0 January 1999 ...
Страница 89: ...Page 70 of 536 Chapter 6 Bracing cabinets against earthquakes 553 3121 210 Standard 3 0 January 1999 ...
Страница 97: ...Page 78 of 536 Chapter 8 Installing a new system 553 3121 210 Standard 3 0 January 1999 ...
Страница 107: ...Page 88 of 536 Chapter 10 Installing the system ground 553 3121 210 Standard 3 0 January 1999 ...
Страница 113: ...Page 94 of 536 Chapter 11 Installing the power supply 553 3121 210 Standard 3 0 January 1999 ...
Страница 125: ...Page 106 of 536 Chapter 12 Adding an expansion cabinet 553 3121 210 Standard 3 0 January 1999 ...
Страница 139: ...Page 120 of 536 Chapter 13 Installing the circuit cards 553 3121 210 Standard 3 0 January 1999 ...
Страница 157: ...Page 138 of 536 Chapter 15 Installing and connecting SDI and Ethernet ports 553 3121 210 Standard 3 0 January 1999 ...
Страница 175: ...Page 156 of 536 Chapter 16 Starting up and testing the system 553 3121 210 Standard 3 0 January 1999 ...
Страница 209: ...Page 190 of 536 Chapter 18 Connecting the trunks 553 3121 210 Standard 3 0 January 1999 ...
Страница 323: ...Page 304 of 536 Chapter 21 Installing Hospitality 553 3121 210 Standard 3 0 January 1999 ...
Страница 419: ...Page 400 of 536 Chapter 23 Pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Страница 455: ...Page 436 of 536 Chapter 24 Changing pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Страница 555: ...Page 536 of 536 Chapter 25 Fault locating and clearing 553 3121 210 Standard 3 0 January 1999 ...