Accessing the Service Console Interface A-3
Nortel IVR 2.5/S Aculab-Based E1 CAS/ISDN PRI Signaling Guide
Using a modem to access the SCI
In North America, a modem that supports a 9600 kbps baud rate is shipped
with every MRS system. Outside North America, a Nortel-recommended
modem is provided by the distributor or customer. This modem must be
connected to the MRS system when the system is installed.
To use a modem to access the SCI, follow these steps:
1
Connect the modem to the MRS port B using a standard
MRS-to-modem cable.
2
Set the terminal parameters as follows:
baud rate
9600
duplex
Full
data bits
7
stop bits
1
parity
even
add LF
off
3
From the remote location, dial in to the modem and wait for an answer.
Once the modem is connected, press <Enter>.
The following message should display:
<system name>
MRS Service Access Port Revision 3.02
Copyright 1991-1996, Nortel. All Rights Reserved
login:
ATTENTION
No modem should be connected to the MRS other than the one shipped
with the system from the factory or provided by the distributor or
customer at installation. Unless a local terminal is connected for a short
period of time to perform local diagnostics or maintenance, the modem
should not be disconnected from the MRS.