24 of 202 About this document
Integrated Network Management Broadband Release 4.1
PG OC 98-13
Issue 1.2
1
The HP 9000 Model 715 has been discontinued by the manufacturer, but will continue to be supported.
2
Please refer to the INM Compatibility section for feature support alignment with S/DMS TransportNode,
S/DMS AccessNode and SONET Radio releases.
3
The HP 9000 Model 715 will support 10 OPC pairs or 20 unprotected OPC spans, 340 NEs and two X
Terminal sessions.
4
The Background Map capability will be disabled for X Terminals running X Windows Version 11
Release 4 or earlier.
5
The HP 9000 Model 735 has been discontinued by the manufacturer, but will continue to be supported.
However, INM 4.1 will be the last release that supports the HP 735.
6
This feature is available when Release 3.1 of Integrated Network Management Broadband is used in
conjunction with the OC-3 Express MOA Release 1.0.
7
The HP 9000 Model 715 will not support this engineering limit. The HP 9000 Model 735 as well as
models C100, C110 and C200 are supported, however they require an increase in RAM. Refer to the INM
Requirements section to obtain the RAM requirements information for each of the supported hardware
platforms.
8
The support of 10,000 NE or 750 OPC/MOAs is achieved through a federated network of up to 25 INM
workstations. For more information, please refer to the INM GUI Engineering Requirements section of
this document.
9
These engineering limits apply only for a standalone INM, i.e. which is not part of a federated network.
10
This feature is available when release 4.0.2 or higher of Integrated Network Management Broadband is
used in conjunction with the OC-3 Express MOA Release 2.0.1 or greater.
11
This feature is available when release 4.0.2 or higher of Integrated Network Management Broadband is
used in conjunction with the OC-3 Express MOA Release 3.1 or greater.
12
This feature is available when release 4.0.2 or higher of Integrated Network Management Broadband is
used in conjunction with the ATM Passport MOA Release 1.0.
OPC/NE
Access
•Direct OPC login
•Direct NE login
•OPC GUI Access
•Direct OPC login
•Direct NE login
•OPC GUI Access
•Direct OPC login
•Direct NE login
•OPC GUI Access
•Direct OPC login
•Direct NE login
•OPC GUI Access
• OC-192 Release 5.0
Web User Interface
Engineering
Limits
•Support for 50 OPC
pairs or 100 unprotected
OPC
spans
3
•Support for 850 NEs
3
•Nine X-terminal
sessions
3
•Two S/DMS Network
Managers connecting to
an OPC
•Access to external
devices via RS232 or
Ethernet ports
•Nine X-terminal sessions
4
•Access to external
devices via RS232 or
Ethernet ports
•Support for 75 OPC
pairs or 150 unprotected
OPC spans
7
•Support for 1200 NEs
7,9
•Four S/DMS Network
Managers connecting to
an OPC
9
•Nine X-terminal sessions
3
•Access to external
devices via RS232 or
Ethernet ports
•Support for 1200 NEs
7,9
•Four S/DMS Network
Managers connecting to an
OPC
9
•Support for 150 OPC
spans
•Support for up to 5500
NEs or 750
OPCs/MOAs
8
•Nine X-terminal sessions
3
•Access to external
devices via RS232 or
Ethernet ports
•Support for 1200 NEs
7,9
•Four S/DMS Network
Managers connecting to an
OPC
9
•Support for 150 OPC
spans
•Support for up to 5500
NEs or 750 OPCs/MOAs
•Engineering limit
increase to 10,000 NEs
8
•Scalability extension for
the Contract Interfaces
Features
S/DMS Network
Manager
Release 5.01
S/DMS Network
Manager
Release 6.01
INM Broadband
Release 3.1
INM Broadband
Release 4.1
Содержание INM 4.1
Страница 2: ......
Страница 8: ...viii of 202 Table of Contents INM Broadband Release 4 1 PG OC 98 13 Issue 1 2...
Страница 26: ...26 of 202 About this document Integrated Network Management Broadband Release 4 1 PG OC 98 13 Issue 1 2...
Страница 100: ...100 of 202 INM 4 1 New Feature Description INM Broadband Release 4 1 PG OC 98 13 Issue 1 2...
Страница 182: ...182 of 202 TCP IP Network Requirements INM Broadband Release 4 1 PG OC 98 13 Issue 1 2...
Страница 198: ...198 of 202 List of Terms INM Broadband Release 4 1 PG OC 98 13 Issue 1 2...
Страница 201: ......