10
FastRAD Installation Guide
Programming
the FastRAD
Before you start, make sure you have completed the
FastRAD
Programming Record
found at the end of this guide. This
record must include the System ID, Auto-answer line number
and Alarm reporting line number.
Table 2 shows the different programming parameters and their
default values. If your programming information does not
specify a value for one of the fields, assign it to the default
value.
Note
: You must program the Required fields for the FastRAD to
operate. Also program any Optional fields that apply to your
system. Auto-answer should be set to ON if unassisted remote
access to the FastRAD is desired.
Table 2 – Programming parameters and default values
Programming Field
Range
Required / Optional
Default
Password
8 to 10 digits
Required
none
System ID
Up to 10 digits
Optional
blank
Auto-answer line number
1 - 999
Required for auto-answering
Line 001
Alarm reporting line number
1 - 999
Required for alarm reporting
Line 001
Local baud rate
300/1200/2400/4800/
9600/19200
Optional
9600
Auto report alarms
ON, OFF
Optional
OFF
Alarm number 1
up to 16 digits
Optional
blank
Alarm number 2
up to 16 digits
Optional
blank
Retry delay
1 - 99 minutes
Optional
15 minutes
Number of retries
0 - 9
Optional
5
Alarm reporting baud rate
Low/Medium/High
Optional
High
Alarm reporting parity
None/Odd/Even
Optional
None
Auto-answer
ON, OFF
Optional
OFF
Answer delay
6 to 60 seconds
Optional
18 seconds
855601 Book : 855601 Guide Page 10 Wednesday, October 29, 1997 4:06 PM