Installing the server and peripheral devices
1005r Server Hardware Installation
51
Connecting the server to the ELAN Subnet
Introduction
Connect the CallPilot server to the Meridian 1 switch or
Succession 1000 system using the ELAN Subnet.
To connect the server to the ELAN Subnet
1
See the diagram on page
to locate the ELAN Ethernet
connector.
2
Connect an RJ-45 network cable from the ELAN hub or Ethernet
switch to the ELAN connector on the server.
Note:
The ELAN hub or Ethernet switch is optional if you use a
cross-over network cable to make a direct point-to-point connection
from the server to the switch. However, if you choose to establish a
direct point-to-point ELAN connection, no other device can connect
to the ELAN Subnet.
ATTENTION
For important considerations about using the ELAN
Subnet in your network, see the
Planning and
Engineering Guide
(555-7101-101).
ATTENTION
To comply with EMC radiation requirements, a Class A
hub must be located 10 m (33 ft.) away from the 1005r
server. You must use shielded Ethernet cables.
Содержание CallPilot 1005r
Страница 6: ...Standard 1 06 6 CallPilot ...
Страница 8: ...8 CallPilot Publication history Standard 1 06 ...
Страница 10: ...Task List Standard 1 06 10 CallPilot ...
Страница 12: ...Contents Standard 1 06 12 CallPilot ...
Страница 34: ...1005r server description Standard 1 06 34 CallPilot ...
Страница 58: ...Installing the server and peripheral devices Standard 1 06 58 CallPilot ...
Страница 72: ...Index Standard 1 06 72 CallPilot ...
Страница 73: ......