Analog terminal adapter installation
89
Nortel Business Communications Manager 450 1.0
Installation — System
NN40160-301 01.04 Standard
July 2009
Copyright © 2006-2009 Nortel Networks
1
Establish a connection to a silent termination on the CO service line with an
analog telephone connected to the ATA2.
2
Replace the analog telephone with the test set.
3
Use RECEIVE/600 OHM/HOLD mode on the test set.
4
Ensure that the analog port terminates correctly in 600 ohms.
5
Ensure that the test set connects in parallel to the service line before you
remove the analog telephone or the line drops.
6
Remove the single-line telephone.
7
Introduce a 1 kHz tone into the analog line at
—
10 dBm, and measure the
level at the CO exchange.
--End--
Configuring the ATA2
Configure the ATA2 using Element Manager or Telset Administration. For
detailed configuration information, see
Nortel Business Communications
Manager 450 1.0 Configuration—Devices
(NN40160-500).