32
Installing the Nortel Ethernet Routing Switch
Maximum Thermal Rating:
512 BTU/Hr
Inrush Current:
20A 120VAC at maximum load, 40A
240VAC at maximum load
Turn on Condition:
1 second maximum after application of AC
power.
Note: 12V output rise time, from 10% to
90%, shall be a maximum of 50 ms and
monotonic under all defined input and
output conditions.
Efficiency:
70% minimum
Nortel Ethernet Power Supply 10 power specification
Output Current:
4.2A maximum
Output Voltage:
-48 VDC
Output Power:
200W maximum
Nortel Ethernet Redundant Power Supply 15 power specification
A DC power supply used with the AC power supply to provide DTE power to
all of the PoE ports in the Nortel Ethernet Routing Switch 5520.
RPS power specifications
Input Voltage:
100 to 240 VAC 50/60 Hz
Input Current:
10A maximum
Inrush Current:
40A maximum (regardless of ambient
temperature)
Output Voltage:
47.5 VDC
Output Current:
12.0A
Output Power:
600W
Nortel Ethernet DC-DC converter module
The Nortel Ethernet Routing Switch 5510 requires an additional DC-DC
converter module to make use of the Nortel Ethernet Routing Switch
Redundant Power Supply Model 15 (RPS 15). This module is required
to connect the RPS 15 to the Nortel Ethernet Routing Switch 5510 but
is not required for other switches in the 5500 Series. For information on
connecting this module to the 5510, see DC-DC Converter Module for the
Baystack 5000 Series Switch (Part Number 215081-A).
Nortel Ethernet Routing Switch 5500 Series
Installation
NN47200-300
2.00
Standard
5.0
7 July 2006
Copyright © 2005 - 2006, Nortel Networks
Nortel Networks Confidential
.