January 2007
Maintaining the Pentium III SBC card
1002rp Server Maintenance and Diagnostics
201
Replacing the Pentium III SBC card
Use system diagnostic tools and refer to error codes to determine
whether the SBC card should be replaced. This section provides
instructions for replacing the SBC card.
Requirements
Before you replace the SBC card, gather the following tools:
one Phillips-head screwdriver
one antistatic wrist strap
the replacement SBC card
cable labels
SBC card connectors and jumpers
Figure 43 on page 202 shows the location of connectors where cables
must be disconnected or connected as part of the procedure to replace the
SBC card. The jumpers shown in this diagram are used in the BIOS
configuration procedures
Содержание 1002rp
Страница 6: ...Standard 1 11 6 CallPilot...
Страница 14: ...Contents Standard 1 11 14 CallPilot...
Страница 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Страница 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Страница 107: ...January 2007 Using CallPilot system utilities 1002rp Server Maintenance and Diagnostics 107 Figure 13 Legend Help tab...
Страница 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Страница 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Страница 150: ...Replacing media drives Standard 1 11 150 CallPilot Figure 31 Replace media drive step 1 G101739...
Страница 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Страница 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Страница 216: ...Index Standard 1 11 216 CallPilot...
Страница 217: ......