Replacing basic chassis components
Standard 1.11
136
CallPilot
Replacing the status display panel
The display is located at the front of the chassis and is cabled to the rear
of the chassis and the alarm board.
To replace the status display panel
1
Power off the server.
2
Remove the top cover and the front bezel from the chassis.
3
Remove the cooling fans (see “Replacing the cooling fan” on
page 126).
The cooling fans block the access to the status panel.
4
Loosen the four Phillips-head screws that secure the status display
panel to the front of the chassis (see A in Figure 26 on page 137)
.
CAUTION
Risk of equipment damage
Use an ESD wrist strap to protect static-sensitive components.
Содержание 1002rp
Страница 6: ...Standard 1 11 6 CallPilot...
Страница 14: ...Contents Standard 1 11 14 CallPilot...
Страница 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Страница 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Страница 107: ...January 2007 Using CallPilot system utilities 1002rp Server Maintenance and Diagnostics 107 Figure 13 Legend Help tab...
Страница 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Страница 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Страница 150: ...Replacing media drives Standard 1 11 150 CallPilot Figure 31 Replace media drive step 1 G101739...
Страница 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Страница 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Страница 216: ...Index Standard 1 11 216 CallPilot...
Страница 217: ......