background image

SIP Line Service

31

Table 5
Shelf slot assignments

Card position
system slot
assignments

PRI Gateway usage for CS 1000
Release 7.0 (Extended Media
Gateway PRI (MGP) package
418- not equipped)

PRI Gateway usage for CS 1000
Release 7.0 (Extended Media Gateway
PRI (MGP) package 418- equipped).

Slot 0

DSP position 2 (32-port
daughterboard)

DSP position 2 as follows:

physical – 96-port DSP DB

physical - 128-port DSP DB

configured – 32-port DSP
daughterboard (where XTRK =
DB32 on Slot 0)

Slot 1–8

Up to eight E1/T1 spans

Up to eight E1/T1 spans

Slot 9–10

Not used

DSP position 2 as follows:
* physical- the same 96 DSP DB used in
Slot 0

* physical - the same 128 DSP DB used
in Slot 0

* configured- 32-port DSP DBs (where
XTRK= DB32 on Slots 9 and 10)

Slot 11–13

DSP position 1 (96-port
daughterboard)

DSP position 1 (96-port DSP DB)

DSP position 1 (128-port DSP DB)

Slot 14

Assigned to DTR and XTD
(optional)

DSP position 1 (128-port DSP DB)

Assigned to DTR and XTD (optional)

Slot 15

Assigned to DTR and XTD
(optional)

DSP position 2 (128-port DSP DB)

Assigned to DTR and XTD (optional)

SIP Line Service

The PRI Gateway interacts with Session Initiation Protocol (SIP) line
service to facilitate the interactions with PSTN networks.

SIPL Package (417) resides on the same hardware platforms as
supported in Release 5.5 with addition to Linux commercial off-the-shelf
(COTS) servers, Common Processor Pentium Mobile (CP PM), Common
Processor Media Gateway (CP MG), and Common Processor Dual Core
(CP DC) cards. Both the SIP Line Gateway and Element Manager reside
on the supported Servers.

Nortel Communication Server 1000

Media Gateway 1000E PRI Gateway Installation and Commissioning

NN43041-311 04.01

4 June 2010

Copyright © 2007-2010 Nortel Networks. All Rights Reserved.

.

Содержание 1000E PRI

Страница 1: ...Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning Release 7 0 Document Revision 04 01 www nortel com NN43041 311...

Страница 2: ...te and reliable except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT AS IS WITHOUT WARRANTY OR CONDITION OF ANY KIND EITHER EXPRESS OR IMPLIED The information and or produc...

Страница 3: ...fting system equipment 13 Power supply cables 14 Handling circuit cards 14 Regulatory information 15 Electromagnetic compatibility 15 Radio and TV interference 18 Safety specifications 18 Notice for U...

Страница 4: ...ack customer supplied 48 Cables and connectors 48 Pinout for a T1 E1 49 Rack mount and ground PRI Gateway components 51 Introduction 51 Rack mount a PRI Gateway 51 Ground a PRI Gateway 52 Install a Me...

Страница 5: ...channel configuration 87 DPNSS DASS configuration DDSL data blocks 93 Configure CE MUX clock controllers 93 Configure PRI PRI2 and DPNSS routes 97 Configure PRI PRI2 and DPNSS trunks 100 Enable PRI sp...

Страница 6: ...141 Automatic backups 142 Manual backups 143 Check backup status 145 Restore backups 146 CLI commands 151 Introduction 151 Organization of CLI commands 151 PRI Gateway alarms 153 Media Gateway Control...

Страница 7: ...gnal Processor DSP daughterboard DB 128 for the Media Gateway Controller MGC card is introduced An MGC card populated with one NTDW78 DB 128 can provide 128 DSP ports The CS 1000E Peripheral Rate Inte...

Страница 8: ...t addresses CR Q01920411 01 to support changes in technical content for the LAN parameters default indicators table May 2008 Standard 02 05 This document is issued to reflect changes in T 1 pinouts Ma...

Страница 9: ...7082 and CR Q01727091 May 2007 Standard 01 01 This document is issued to support Communication Server 1000 Release 5 0 Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and...

Страница 10: ...New in this Release Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041 311 04 01 4 June 2010 Copyright 2007 2010 Nortel Networks All Rights Reserv...

Страница 11: ...technical issues sign up for automatic notification of new software and documentation for Nortel equipment open and manage technical support cases Getting help over the telephone from a Nortel Soluti...

Страница 12: ...ERC for your product or service go to www nortel com erc Getting help through a Nortel distributor or reseller If you purchased a service contract for your Nortel product from a distributor or authori...

Страница 13: ...safety instructions before handling the equipment WARNING Failure to follow the safety instructions in this chapter could result in personal injury CAUTION Failure to follow the safety instructions in...

Страница 14: ...n antistatic wrist strap when handling circuit cards or their components Follow these precautions when handling circuit cards 1 Unpack or handle cards away from electric motors transformers or similar...

Страница 15: ...asures Table 1 EMC specifications Jurisdiction Standard Description United States FCC CFR 47 Part 15 FCC Rules for Radio Frequency Devices see Note 1 Canada ICES 003 Interference Causing Equipment Sta...

Страница 16: ...imits and methods of measurement of radio disturbance characteristics of information technology equipment see Note 2 Japan VCCI Rules for Voluntary Control Voluntary Control Council for Interference b...

Страница 17: ...he equipment Note 2 EN 55022 CISPR 22 statement WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take ade...

Страница 18: ...ed with the equipment If you use any other equipment it may cause failures malfunctioning or fire Power cords shipped with this equipment must not be used with any other equipment In case the precedin...

Страница 19: ...t to file a compliant with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equ...

Страница 20: ...Germany Telecom specifications The system meets the following European technical regulations CTR 4 CTR 12 CTR 13 Supported interfaces Digital interfaces are approved based on European specifications...

Страница 21: ...digital trunk gateway that supports up to eight E1 T1 spans ATTENTION At this time DTI and JDMI are not supported on the MG1000E PRI Gateway MGP Only E1 T1 PRI protocols are supported on this gateway...

Страница 22: ...ortel home page www nortel com Applicable systems This document applies to the CS 1000E Release 7 0 system ATTENTION When you upgrade the software memory and hard drive upgrades can be required on the...

Страница 23: ...s This document references the following NTPs Communication Server 1000E Installation and Commissioning NN43041 310 ISDN Primary Rate Interface Features Fundamentals NN43001 569 B1 ISDN Primary Rate I...

Страница 24: ...echnical Documentation link under Support Training on the Nortel home page www nortel com Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041 311 04...

Страница 25: ...requirements Device ELAN connection ELAN port Address requirement TLAN connection TLAN port Address requiremen t MGC 1 100baseT for HA 2 for SA 1E ELAN on back of chassis for HA NA 1 100baseT for HA 2...

Страница 26: ...e Rack mounting and grounding the PRI Gateway Rack mount and ground PRI Gateway components page 51 Installing the MGC card and DSP DBs Install a Media Gateway Controller and DSP daughterboard page 53...

Страница 27: ...30 Introduction The PRI Peripheral Rate Interface Gateway is a digital trunk gateway that enables access to the Public Switched Telephone Network PSTN for telephones and other IP Phones or other PBXs...

Страница 28: ...e D channel daughterboard to serve two E1 T1 spans has onboard clock reference functionality eliminates the need for a clock controller daughterboard which is system software transparent supports full...

Страница 29: ...aughterboard for each slot and one clock controller daughterboard is used The PRI Gateway uses the MGCr with its DSP DBs along with an E1 T1 card that supports four to eight E1 T1 spans with up to fou...

Страница 30: ...nel 2 0 MB PRI DCHI NTAK93AB Nondownloadable D channel ATTENTION The PRI Gateway eliminates the need for a clock controller daughterboard The clock controller functionality is provided internally Shel...

Страница 31: ...ughterboard DSP position 1 96 port DSP DB DSP position 1 128 port DSP DB Slot 14 Assigned to DTR and XTD optional DSP position 1 128 port DSP DB Assigned to DTR and XTD optional Slot 15 Assigned to DT...

Страница 32: ...ine configuration see SIP Line Fundamentals NN43001 508 For information about SIP Line installation see Linux Platform Base and Applications Installation and Commissioning NN43001 315 Nortel Communica...

Страница 33: ...ware components required for installing the PRI Gateway The PRI Gateway is a digital trunk gateway that supports up to eight E1 T1 spans It houses an existing Media Gateway Controller MGC with expansi...

Страница 34: ...T1 card NTDW70AA that provides a base of four spans and allows an additional four spans with an expansion daughterboard NTDW75AA for a total of a possible eight spans The E1 T1 card includes four add...

Страница 35: ...Gateway components that can be ordered as separate items Table 6 Replaceable components NT code Description New or existing NTDW72AAE5 PRI Gateway chassis Existing NTDW71AAE5 PRI Gateway Power Supply...

Страница 36: ...e E1 T1 card page 36 Figure 5 Faceplate for the E1 T1 card Figure 6 Backplane for the E1 T1 card The E1 T1 card excluding DCH daughterboards provides the following hardware features Nortel Communicati...

Страница 37: ...ctions to the ELAN subnet 33 LEDs on the faceplate to display diagnostic information onboard capability for DPNSS DASS D channels used to mount downloadable D channel daughterboards NTBK50AA emulation...

Страница 38: ...he NTAK93AB D channel handler The E1 T1 card requires one slot on the 19 inch 2u MGP shelf The other slot on the shelf is reserved for the Media Gateway Controller E1 T1 card expansion daughterboard T...

Страница 39: ...E1 T1 card page 39 Table 7 LED functionality for the E1 T1 card Group LED Name Color Functionality Power 1 LED PWR Green Lit when power is OK Fan 1 LED FAN Red Lit when one of the fans in the cooling...

Страница 40: ...rocessing requests The MGC card has two expansion slots for DSP daughterboards A MGC card can provide a maximum of 256 DSP ports 2x128 port DSP daughterboards For more information about the Media Gate...

Страница 41: ...ble D channel configuration as follows pure DDCH daughterboard using only port 1 pure DDCH daughterboard using only port 0 and 1 pure DCHI daughterboard using port 1 pure onboard DPNSS DASS mixed conf...

Страница 42: ...the lower left daughterboard port 1 is physically mapped to span 6 of the PRI Gateway MGC IPE card slot 6 from a system software perspective the lower right daughterboard port 1 is physically mapped t...

Страница 43: ...span example page 44 for samples of DCH configurations The examples show the use of four E1 T1 spans as well as the use of eight spans using the E1 T1 expansion daughterboard The examples describe pu...

Страница 44: ...t supported Not supported Not supported 3 4 Upper right DDCH Port 1 Upper right DCHI Port 1 Upper right DDCH Port 1 4 5 Not supported Not supported Not supported 5 6 Lower left DDCH Port 1 Lower left...

Страница 45: ...or the PRI Gateway the following software package for the functionality that allows the use of port 0 or port 1 is provided in CS 1000 Extended Media Gateway PRI MGP package 418 For the example descri...

Страница 46: ...6 Lower left DDCH Port 1 DCHI Port 1 DCHI Port 1 6 7 Lower right DDCH Port 0 DCHI Port 1 DCHI Port 1 7 8 Lower right DDCH Port 1 DCHI Port 1 DCHI Port 1 8 ATTENTION For the PRI Gateway the following s...

Страница 47: ...With the use of a DDCH daughterboard a DCH interface can be defined on any span However if one of the spans is not used for a DCH interface it can be used for BCHs served by a DCH interface that is c...

Страница 48: ...stomer supplied The PRI Gateway is mounted in a customer supplied 19 inch rack For more information about the rack and the other components it holds see Communication Server 1000E Installation and Com...

Страница 49: ...06E6 up to eight shielded RJ 45 E1 T1 cables All the cables listed here including the MGC cables as well as the connectors listed here are not provided by Nortel and are the responsibility of the dist...

Страница 50: ...r crossover CAT5 Ethernet cables with RJ 48 pinned CSUs and 568 pinned patch panels The RX and TX signals are reversed for standard CAT5 Ethernet cables compared to E1 T1 cables and can cause problems...

Страница 51: ...teway components page 52 For more information about the layout of a CS 1000E equipment rack see Communication Server 1000E Installation and Commissioning Rack mount a PRI Gateway To install the PRI Ga...

Страница 52: ...Only a qualified person must make the connection in the AC electrical panel Procedure 2 Grounding PRI Gateway components Step Action 1 Disconnect the AC power cord from the power outlet 2 Install a 6...

Страница 53: ...s and place the MGC on a safe Electrostatic Discharge ESD surface 2 Place the DSP daughterboard in either daughterboard position 1 or daughterboard position 2 or both depending on how the daughterboar...

Страница 54: ...teway Controller and DSP daughterboard Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041 311 04 01 4 June 2010 Copyright 2007 2010 Nortel Networks...

Страница 55: ...face DCHI daughterboard NTAK93AB for DPNSS DASS protocols See Procedure 4 Installing NTBK51AA NTBK51CA and the NTAK93AB daughterboards on an E1 T1 card page 56 Install the E1 T1 expansion daughterboar...

Страница 56: ...configuration the NTBK51BA is used on OPT11 systems that support only one span The NTAK93AB DCHI daughterboard supports only one E1 span CAUTION You must wear the static discharge bracelet located in...

Страница 57: ...93AB daughterboards from an E1 T1 card page 57 Procedure 5 Removing NTBK51AA NTBK51CA and NTAK93AB daughterboards from an E1 T1 card Step Action 1 Change the removed E1 T1 span configuration to not de...

Страница 58: ...ard 2 Mount the expansion daughterboard so that it mates with connector pins on the E1 T1 card 3 Define the new loops and DCH interfaces in the system software 4 Configure the E1 T1 parameters through...

Страница 59: ...d positioning page 60 shows the position of the header marked J2 and the expansion daughterboard in position on the E1 T1 card Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installa...

Страница 60: ...the Media Gateway Controller See Procedure 7 Installing an E1 T1 card on a PRI Gateway chassis page 60 For information about the connectors and cables see Connect PRI Gateway components page 63 Proce...

Страница 61: ...nfiguration administration and maintenance are done through the Web interface See Procedure 8 Connecting the RS 232 cable page 61 Procedure 8 Connecting the RS 232 cable Step Action 1 Connect the RS 2...

Страница 62: ...E1 T1 card and daughterboards Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041 311 04 01 4 June 2010 Copyright 2007 2010 Nortel Networks All Rig...

Страница 63: ...u chassis The upper slot is reserved for the MGC The MGC can be connected to a Layer 2 switch to handle signaling between the Call Server and the PRI Gateway If two of the ELAN network interfaces of t...

Страница 64: ...network connections Figure 12 Single server port configuration no dual homing page 65 and Figure 13 Single server port configuration dual homing nondistributed page 66 show two different connections t...

Страница 65: ...cost effective single server configuration Figure 12 Single server port configuration no dual homing A single server supports multiple MGCs using external networking equipment Figure 13 Single server...

Страница 66: ...to ensure there is no single point of failure Nortel recommends this configuration for highest reliability in a single CPU Call Server configuration Note that the Layer 2 switch must be partitioned i...

Страница 67: ...ding of the MGC network connections is allowed up to a maximum of two chassis The MGCs can be cabled directly without the need for external Layer 2 switches which is the type of configuration recommen...

Страница 68: ...Connect a standard CAT5 patch cable to the TLAN network interface on the adaptor 2 Connect the other end of the standard CAT5 patch cable to an RJ 45 TLAN network interface on the Layer 2 switch End C...

Страница 69: ...GC on the Call Server You must configure the MGC itself The order of these tasks is not critical However Nortel recommends that you configure the MGC on the Call Server before you install the MGC You...

Страница 70: ...IPMG IP Media Gateway The following prompts are for IPMG superloops only IPR0 nn nn nn nn Shelf 0 IPMG Uplink IP address CR to skip to IPR1 when configuring new superloop X to remove IPR0 DES0 and ZO...

Страница 71: ...if the IPMG is not associated This prompt allows for the association of the MGTDS with a particular IPMG supl IPMG superloop sh IPMG shelf MGCONF aaa bbb ccc ddd Allow the configuration of up to four...

Страница 72: ...all Server After configuration is complete and the MGC has rebooted the MGC attempts to register to the Call Server The Call Server then attempts to match the IP address configured in LD 97 for this P...

Страница 73: ...auto negotiate y n y ELAN security is Disabled change y n y Enable ELAN security y n y Optimized Security level change level y n y Enter security level OPTI FUNC or FULL opti Change public key y n y...

Страница 74: ...subnet mask 255 255 254 0 ELAN gateway IP 47 11 216 1 Primary CS IP 47 11 216 61 Change MGC advanced parameters y n y TLAN is set to auto negotiate change y n y Note Turning off auto negotiate on the...

Страница 75: ...47 11 216 79 ELAN subnet mask 255 255 254 0 ELAN gateway IP 47 11 216 1 Primary CS IP 47 11 216 61 TLAN set to auto negotiate ELAN set to auto negotiate ELAN security Enabled level is Optimized Securi...

Страница 76: ...daughterboard to support Voice Gateway Channels using LD 14 page 80 Configure Voice Gateway Channels in Element Manager Procedure 14 Configuring an MGC in Element Manager page 76 describes how to con...

Страница 77: ...you select MGC the remaining fields automatically fill in CE E1 E CT T2 and T Click Submit 4 Click Submit The window shown in Figure 17 IPMG MGC configuration page 78 appears Nortel Communication Ser...

Страница 78: ...d IPv6 In Release 7 0 Global unicast IPv6 addressing is the only supported IPv6 address type For the DSP daughterboards connected select the type and enter the IP addresses IPv4 or IPv6 After configur...

Страница 79: ...s Figure 19 Add VGW channels 7 Select the number of required channels the Terminal Number the superloop and shelf numbers of the MGC the card number and the unit 8 Provide a name and the daughterboard...

Страница 80: ...MGC and the DSP daughterboards using Element Manager For more information see Configure Voice Gateway Channels in Element Manager page 76 Procedure 15 Configuring a DSP daughterboard to support Voice...

Страница 81: ...ion of the gateway channels XTRK DB96 96 port DSB daughterboard CUST xx The customer to which the IPTN resources are assigned REQ a a Request CHG NEW TYPE VGW Voice Gateway TN l s c u TN of the first...

Страница 82: ...hannels XTRK DB32 32 port DSB daughterboard CUST xx The customer to which the IPTN resources are assigned 4 Exit from LD 14 Enter the command End Configuring the DTR For detailed instructions on confi...

Страница 83: ...DPNSS DASS D channels in the PRI Gateway using LD 17 page 90 Procedure 22 Configuring DPNSS DASS D channel interface using LD 74 page 93 Procedure 23 Configuring a digital data block using LD 73 page...

Страница 84: ...ing basic LAN parameters by CLI page 113 Procedure 41 Accessing the command line interface over the Web page 114 Access and configure an E1 T1 card through the Web page 114 Procedure 42 Accessing the...

Страница 85: ...ble 16 PRI loop configuration LD 17 Prompt Response Description REQ CHG Change existing data TYPE CEQU Make changes to common equipment parameters CFN YES Common equipment DLOP loop dd ff Digital loop...

Страница 86: ...D 17 Prompt Response Description REQ CHG Change existing data TYPE CEQU Make changes to common equipment parameters CFN YES Common equipment PRI2 loop Digital loop 2 0 Mb 0 254 MG_CARD supl sh card Th...

Страница 87: ...shelf card ATTENTION If using the NTAK93AB daughterboard odd card numbers are applicable 1 3 5 7 If using the onboard DPNSS DASS odd and even numbers are applicable 1 2 3 4 5 6 7 8 End D channel conf...

Страница 88: ...te Interface Features Fundamentals NN43001 569 B1 Use Procedure 19 Configuring a D channel interface to support PRI NI2 using LD 17 page 88 to configure the PRI NI2 D channel interface in the PRI Gate...

Страница 89: ...RI This D channel is used for Primary Rate only IFC NI2 Interface type for the D channel DCHL 0 254 Loop number for the D channel See DLOP loop number SIDE USR NET The system is network user side End...

Страница 90: ...8 PORT 0 1 Port number of the NTBK51AA NTBK51CA for the D channel USR PRI This D channel is used for Primary Rate only IFC EURO Interface type for the D channel CNTY aaaa Country DCHL 0 254 Loop numb...

Страница 91: ...93AB for DPNSS DASS D channel For a DPNSS DASS D channel the port is always 1 DES DPNSS Designator up to 16 alphanumeric characters DPNS YES Digital Private Network Signaling End D channel configurati...

Страница 92: ...ed physical location of DDCH NTBK51AA NTBK51CA daughterboard in the PRI Gateway The format is superloop shelf number card number even card number 4 PORT 0 Port 0 of the NTBK51AA NTBK51CA daughterboard...

Страница 93: ...igital Signaling Link S2 0 DCHI switch setting the normal addressing mode for MGP DDSL 0 15 The D channel logical port number entered in LD 17 SIGL DA DPNSS1 DASS2 digital signaling DDCS 0 254 Loop nu...

Страница 94: ...Q aaa Request aaa CHG END NEW OUT or PRT TYPE DDB Digital data block MGCLK sl s c Superloop shelf card number of PRI containing the Primary Clock Reference The card number 1 to 8 should match the PRI...

Страница 95: ...s using LD 73 Step Action 1 Log on to the CS 1000E 2 To access LD 73 enter LD 73 3 Enter the responses shown in Table 25 Configuration for PRI2 data block system timers LD 73 page 95 Table 25 Configur...

Страница 96: ...g the PRI2 loop timers using LD 73 page 96 to configure the PRI2 loop timers and thresholds Procedure 25 Configuring the PRI2 loop timers using LD 73 Step Action 1 Log on to the CS 1000E 2 To access L...

Страница 97: ...the PRI trunk route is also supported on other PRI interface types Procedure 26 Configuring PRI trunk routes using LD 16 Step Action 1 Log on to the CS 1000E 2 To access LD 16 enter LD 16 3 Enter the...

Страница 98: ...ks The example given in Table 28 PRI2 route LD 16 page 98 is specific to the EURO interface however the PRI trunk route is also supported on other PRI2 interface types Procedure 27 Configuring PRI2 tr...

Страница 99: ...route TARG 0 1 31 Trunk Access Restriction Group Number End Procedure 28 Configuring DPNSS DASS trunk routes using LD 16 page 99 describes how to configure Route Data Block data required for DPNSS tr...

Страница 100: ...PRI2 and DPNSS trunks Procedure 29 Configuring PRI and PRI2 trunks with Trunk Data Block data using LD 14 page 100 describes how to configure the Trunk Data Block data required for PRI and PRI2 trunk...

Страница 101: ...direct access CLS aaaa Class of Service End Procedure 30 Reconfiguring existing Dchannels on an NTBK51AA NTBK5 1CA page 101 describes how to change the protocol on an established D channel using LD 2...

Страница 102: ...l Where x y and z are the values returned in LD 22 End Procedure 31 Changing the protocol on an established D channel using Element manager Step Action 1 Log on to Element Manager 2 In the sidebar cli...

Страница 103: ...runk Data Block data This configuration is required for both real RDC and virtual VDC channel types ATTENTION VDC configuration is not required for DASS signaling Procedure 32 Configuring the DPNSS DA...

Страница 104: ...A card or the NTAK93AB daughterboard and enable the clock controller If you use the NTBK51AA NTBK51CA daughterboard follow the procedure described in Procedure 33 Enabling the NTBK51AA NTBK51CA daught...

Страница 105: ...K93AB daughterboard Step Action 1 In LD 75 enter the command to enable all PRI loops ENL DDCS 1 2 Enter the command to enable the DCHI where the DCHI is enabled but all channels are disabled ENL DDSL...

Страница 106: ...T1 card Configure basic parameters through command line interface Follow Procedure 36 Configuring basic parameters through CLI page 106 to configure the basic parameters Procedure 36 Configuring basi...

Страница 107: ...atus of the E1 T1 spans IP address The window displays one line for each E1 T1 span The Protocol column displays E1 T1 not defined The Usage column displays what hardware is used for D channel DDCH DC...

Страница 108: ...s See Procedure 37 Entering LAN parameters page 108 Procedure 37 Entering LAN parameters Step Action 1 To log on to the CLI enter the command admin The system displays the current directory root direc...

Страница 109: ...this value system name e g first MGP report aging days 5 e g 14 subnet mask 255 255 255 0 e g 255 255 255 0 ELAN gateway address 1 1 1 1 e g 141 226 128 254 ELAN IP address 1 1 1 124 e g 141 226 128...

Страница 110: ...can also verify the network connections from a PC on the ELAN subnet See Procedure 39 Verifying a network connection from a PC page 111 Procedure 38 Verifying a network connection from the CLI Step A...

Страница 111: ...39 Verifying a network connection from a PC Step Action 1 On a PC click Start and the select Run from the Start Menu 2 In the Open box enter the following and click OK ping xxx xxx xxx xxx Where xxx x...

Страница 112: ...ported through Telnet FTP You can connect a modem to the E1 T1 card through a serial port 9 pin connector The E1 T1 card ignores all RS 232 control signals so a modem eliminator null modem is required...

Страница 113: ...tial configuration of an E1 T1 card through the command line interface Follow the steps in Procedure 40 Configuring basic LAN parameters by CLI page 113 After the initial configuration you carry out a...

Страница 114: ...stration console and click CLI on the toolbar at the top of the screen A separate window opens 2 Enter commands and text as needed End Access and configure an E1 T1 card through the Web You can config...

Страница 115: ...tp xxx xxx xxx xxx The window shown in Figure 26 MG 1000E PRI Gateway logon window page 115 appears Figure 26 MG 1000E PRI Gateway logon window 2 Click Login The dialog box shown in Figure 27 Logon di...

Страница 116: ...System Overview window 4 In the left pane click System Settings End Define administrative users You can define a maximum of 10 administrative users See Procedure 43 Adding administrative users throug...

Страница 117: ...ative user settings click Submit End View and change administrative user settings To view and change administrative user settings see Procedure 44 Viewing and changing administrative user settings thr...

Страница 118: ...e user click Reset Password The user s password is reset to Admin 5 To modify user attributes click the user name you want to modify The window shown in Figure 31 Edit User Attributes window page 118...

Страница 119: ...119 appears Figure 32 Change Password window 2 Enter the current password 3 Enter the new password in the New password field and enter it again in the Confirm new password field 4 Click Submit End Co...

Страница 120: ...roller 3 In the System Name field type up to 15 alphanumeric characters for the name of the system 4 In the IP address of E mail Server field type the IP address The E1 T1 card uses this address to se...

Страница 121: ...d Configure ISDN E1 T1 trunks To define the parameters for the ISDN E1 T1 trunks see Procedure 47 Configuring ISDN E1 T1 trunks page 121 This basic configuration is used by the E1 T1 card to shorten a...

Страница 122: ...em software IPE card slots 2 4 6 and 8 c For each T1 span configure the parameters as described in Table 33 Parameters for T1 spans page 122 ATTENTION For T1 spans on the E1 T1 card the following Web...

Страница 123: ...Web interface configuration and the Call Server configuration exists Table 34 Parameters for E1 spans Parameter Value CRC4 No Impedance 120 ohm Shield Ground No for 75 Ohm only e To save the parameter...

Страница 124: ...onfigure an E1 T1 card Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041 311 04 01 4 June 2010 Copyright 2007 2010 Nortel Networks All Rights Rese...

Страница 125: ...trunk loops using LD 60 page 126 Procedure 49 Maintaining the clock controller using LD 60 page 127 Procedure 50 Maintaining the DDCH using LD 96 page 127 Procedure 51 Starting up the PRI page 128 Pr...

Страница 126: ...Mb s DTI PRI ENCH l ch Enable channel ch of DTI PRI loop ENLL loop Enable network and DTI PRI cards of loop ENYL loop Enable yellow alarm processing for loop SLFT loop Invoke hardware self test on lo...

Страница 127: ...able system clock controller on specified superloop and shelf ENL CC l s Enable system clock controller on specified superloop and shelf SSCK l s Get status of system clock on specified superloop and...

Страница 128: ...STAT DCH x Get status of one or all D channels STAT MON x Display the incoming and outgoing monitoring status of one or all D channels DIS MSDL sl s c ALL Disable DCHI card sl s c ENL MSDL sl s c FDL...

Страница 129: ...s disabled 4 To enable the NTBK51AA NTBK51CA DDCH daughterboard enter LD 96 ENL MSDL sl s c The DDCH card is downloaded and enabled The D channel is disabled 5 To enable the D channels enter LD 96 ENL...

Страница 130: ...status Step Action 1 Check the status LEDs on all PRI spans For normal operation only the green ENB DIS LED is lit 2 Check the associated DCH LED upper left upper right lower left lower right If both...

Страница 131: ...TOTAL 24HR SLPREP XXXXXXXXX TOTAL 24HR SLPDEL XXXXXXXXX TOTAL 24 HOUR G2 AIS XXXXXXXXX TOTAL 24 HOUR G2 LFAS XXXXXXXXX TOTAL 24 HOUR G2 LMAS XXXXXXXXX TOTAL 24 HOUR G2 RAI XXXXXXXXX TOTAL 24 HOUR G2...

Страница 132: ...PRI loop l ENL DTRC l c Enable real channel loop channel DIS DDSL n Disable DCHI port n DIS DDCS l Disable PRI loop n DISI DDCS l Disable all channels loop l as they become idle DIS DTRC l c Disable r...

Страница 133: ...r DCH the red ENB DIS LED is lit Figure 37 IDA startup 2 To enable the PRI enter LD 75 ENL DDCS loop The response is OK 3 To enable the DCHI NTAK93AB enter LD 75 ENL DDSL n The response is OK STAT DDS...

Страница 134: ...he DPNSS DASS status is not as shown in these steps complete the check and proceed to DPNSS DASS fault clearing procedures For more information about DPNSS DASS and fault clearing procedures see DPNSS...

Страница 135: ...led 5 Check that the PRI cables are connected to the E1 T1 span connectors End Inventory cards Printing a PRI Gateway inventory LD 117 All installed PRI Gateways are included in the output of the Inve...

Страница 136: ...is being used field 3 PEC code NTDW70AAE5 field 4 release of the card field 5 factory code source code serial number and manufacturing data of the card Only E1 T1 cards and spans that are configured i...

Страница 137: ...page 143 Procedure 62 Restoring a file through FTP page 146 Procedure 63 Restoring a file through upload on a PC page 148 Reports Reports are stored by the E1 T1 card on a daily basis Each day is sto...

Страница 138: ...Report End Upgrades You can upgrade the system and check the status of the software upgrades Software upgrade Software upgrades are performed through FTP See Procedure 57 Performing a software upgrade...

Страница 139: ...ath Login and Password fields 5 Click Get Files 6 To complete the installation of the software click Upgrade Restart The E1 T1 card installs the new software and restarts the system Because the system...

Страница 140: ...restarts the system Because the system restarts your Web session ends You must log on again to resume working through the Web interface 5 If the upgrade fails or if you want to check the status of the...

Страница 141: ...1 card supports automated scheduled backups or manual backups to schedule an automated backup see Automatic backups page 142 to perform a manual backup see Manual backups page 143 For each type of bac...

Страница 142: ...rameters To perform the test select a daily backup and the nearest hour and check to see that the backup occurs at the appointed time Procedure 60 Scheduling an automatic backup Step Action 1 On the H...

Страница 143: ...dress of the server to which you want to back up the file the path to the backup file the user id and the password 4 Select Configuration data or Error Reports or both 5 Click Submit End Manual backup...

Страница 144: ...d in the Basic Setting window For more information see Configure basic system parameters page 119 b FTP to remote address If you select this option you must enter the IP address of the server the file...

Страница 145: ...ndow page 146 On the Home System Overview window select Backups View Backup History Log or Backups View last backup details Figure 45 View Backup History Log window The View Backup History Log window...

Страница 146: ...re a file in two ways the FTP method See Procedure 62 Restoring a file through FTP page 146 the upload method on a PC See Procedure 63 Restoring a file through upload on a PC page 148 Procedure 62 Res...

Страница 147: ...ck Restore Restart The system restarts and your Web session ends You must log on again to resume working through the Web interface 5 You can view the details of the restore as shown in Figure 48 View...

Страница 148: ...kup file to the PC 2 On the Home System Overview window select Restore Execute Manual Restore The window shown in Figure 49 Execute Manual Restore window Upload page 149 appears Nortel Communication S...

Страница 149: ...m restarts and your Web session ends You must log on again to resume working through the Web interface 6 You can view the details of the restore as shown in Figure 48 View Last Restore Details window...

Страница 150: ...orts upgrades and backups Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041 311 04 01 4 June 2010 Copyright 2007 2010 Nortel Networks All Rights R...

Страница 151: ...mote access to the E1 T1 card page 112 Organization of CLI commands CLI commands are organized in a tree structure as shown in Figure 50 Tree structure of CLI commands page 152 Navigating the CLI tree...

Страница 152: ...ure 50 Tree structure of CLI commands Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041 311 04 01 4 June 2010 Copyright 2007 2010 Nortel Networks...

Страница 153: ...E CRC4 errors reported by remote side Slip AIS All one RAI ts0 Remote alarm indication Los Loss of signal LFAS Lost frame alignment signal Level 2 CLMAS Lost of CRC4 frame alignment signal T1 ISDN SF...

Страница 154: ...llow alarm Los Loss of signal LFAS Lost frame alignment signal Level 2 ESF CLMAS Loss of CRC6 frame alignment signal Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and C...

Страница 155: ...watchdog expired User initiated Software error Depending on the reason code contact Nortel support TTY LOG SNMP MGC0001 Critical Warm start of the MGC supl shelf occurred Reason Normal after cold star...

Страница 156: ...and network connections Confirm the password file exists in the appropriate directory on the Call Server TTY LOG SNMP MGC0008 Major MGC supl shelf detected a problem with loadware loadware version re...

Страница 157: ...for an SSC MG 1000E is 4 Do not configure more than 4 MGCNF loops for an SSC MG 1000E TTY LOG SCH2156 Info The maximum number of MGCNF loops that can be configured for a MGC MG 1000E is 2 Do not confi...

Страница 158: ...roller system alarms events and messages Nortel Communication Server 1000 Media Gateway 1000E PRI Gateway Installation and Commissioning NN43041 311 04 01 4 June 2010 Copyright 2007 2010 Nortel Networ...

Страница 159: ...ng reports 137 DPNSS loop configuration 85 DPNSS spans enabling through software 105 DPNSS trunk routes 97 DPNSS trunks 100 DPNSS DASS 132 DSP daughterboard configuring Voice Gateway Channels 80 insta...

Страница 160: ...I PRI2 trunks 100 PRI PRI2 trunks routes 97 PRI1 EURO D channel interface 87 PRI2 loop configuration 85 R redundancy 35 remote access 113 FTP 113 over the Web 114 Telnet 113 removing daughterboards 57...

Страница 161: ......

Страница 162: ...le except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT AS IS WITHOUT WARRANTY OR CONDITION OF ANY KIND EITHER EXPRESS OR IMPLIED The information and or products described...

Отзывы: