background image

 

CRC200S Quick Installation Guide

 

Scope 

This guide provides the basic instructions for installing, configuring and adding sequentially 
numbered cards to the CRC200S Controller. Refer to the User Guide for detailed information on 
using the CRC200S. 

Fitting the CRC200S 

Release the front cover from the main unit by pressing the securing buttons at the base of the unit 
while you lift off the cover from the bottom (hinging the cover at the top).  

Carefully unplug the ribbon cable linking the cover to the main unit (avoid pulling or bending the 
ribbon cable). Completely remove the front cover. 

Fit the unit to the mounting surface using the 2 keyhole slots and 2 mounting holes in the back 
plate. Use 4 appropriate screws or nuts/bolt (M4) according to the type of mounting surface. 

After wiring the unit, support the cover with one hand and carefully re-insert the end of the ribbon 
cable into its socket. Refit the cover by engaging the top of the cover with the top of the housing 
and hinging in the bottom of the cover until the securing buttons are fully engaged in the housing.  

Power & Cabling Requirements 

N/O
N/C

Comm

N/O
N/C

Comm

Relay 1

Relay 2

Reader

Voltage

Select

Reader 1

Reader 2

5V

As supply

12 - 24 VDC

D+

D-

GN

D

RS485

+v

e

-v

e

Clk/

D1

Da

t/

D0

LE

D

C

apt

0v

RE

X

Mon

+

-

  

Reader Voltage Settings 

Each of the two reader interfaces includes a power supply output that can be individually set to 
either 5V or “supply voltage” to match the requirements of the connected reader. The voltage for 
each reader is set on a jumper to the left of the corresponding terminal block. To avoid damage to 
the readers, you must set the correct voltage for each reader before applying power to the 
CRC200S.  For use with 12V readers, the power supply to the CRC200S must be 12VDC. 

If you are in any doubt about the output voltage to the reader, apply power to the CRC200S without 
connecting the readers and measure the voltage across the ve and -ve connector pins.

 

 

 

  

Issue 

02 

Содержание CRC200S

Страница 1: ...bon cable into its socket Refit the cover by engaging the top of the cover with the top of the housing and hinging in the bottom of the cover until the securing buttons are fully engaged in the housing Power Cabling Requirements N O N C Comm N O N C Comm Relay 1 Relay 2 Reader Voltage Select Reader 1 Reader 2 5V As supply 12 24 VDC D D GND RS485 ve ve Clk D1 Dat D0 LED Capt 0v REX Mon Reader Volta...

Страница 2: ... features The full menu structure is shown at the end of this guide for general guidance The required basic programming actions are 1 Set relay operation times 2 Add and validate cards as required with or without cards available Once these actions have been carried out the CRC200S is ready for basic use Programming The CRC200S is programmed using the 12 buttons and the LCD display Note The CRC200S...

Страница 3: ... only one card is to be validated P r o g r a m C a r d s A c c L e v e l x Enter the Access Level assigned to the card s and press Level 1 valid on both readers P r o g r a m C a r d s C a p t 1 n o Use to toggle between Yes or No to indicate whether these cards should be captured at Reader 1 and press P r o g r a m C a r d s C a p t 2 n o Use to toggle between Yes or No to indicate whether these...

Страница 4: ...rogram Cards Verify Cards Set PIN Codes Installer Clear Cards Clear Events Time Zones Access Levels Config Set APB Mode Date Time Door Open TZ Card Format Card test P 0 P 0 0 0 0 0 0 0 P 0 0 0 0 0 0 Press Press to enter a menu item Press to escape a menu item or move up a level Issue 02 ...

Отзывы: