Table 3: Status Indicators
Status Indicator
Type of Status Indicator
Description
SSPA Detected Power
information only
the measured output power of
the amplifier
Delta Power Output
variable range alarms
difference in the requested
power versus the measured
output power
Rx Downconverter Level
information only
Rx signal strength indicator
LNB Current
variable range alarms
DC current the LNB consumes
SSPA Temperature
variable range alarms
internal temperature of the
amplifier
Rx Downconverter Lock
Binary Alarm
The Local Oscillator PLL lock
status for the downconverter
in the Rx Spectrum Analyzer
must be locked to use the Rx
spectrum analyzer.
Tx Downconverter Lock
Binary Alarm
The Local Oscillator PLL lock
status for the downconverter
in the Tx Spectrum Analyzer.
Note that this is not used on
the GLOBETrekker™ and can
be ignored.
Environmental Monitor
Binary Alarm
Indicates whether the
environmental conditions
within the GLOBET
rekker™
are suitable for operation.
Details tab will show the full
values of all components. The
ACU component will turn to
alarm if the desiccant needs
changing.
3.1.1 Software Troubleshooter
In the event of an alert requiring user attention, either clicking the alarm button or selecting the
troubleshooter from the help menu will give the user directions to resolve the issue.
A pop-up window will give the user a list of actions that should be attempted to resolve the issue