Norgren Micro-Fog L73M Скачать руководство пользователя страница 1

L73M, L73C 

 Installation & Maintenance 

Instructions

TECHNICAL DATA

Fluid: Compressed air

Maximum pressure: 

Transparent bowl: 10 bar (150 psig) 

Metal bowl: 17 bar (250 psig) 

Operating temperature*: 

Transparent bowl: -20° to +50°C (0° to +125°F) 

Metal bowl: -20° to +80°C (0° to +175°F) 

*  Air supply must be dry enough to avoid ice formation 

at   temperatures below +2°C (+35°F).

Start point (minimum flow required  for lubricator 

operation) at 6,3 bar (90 psig) inlet pressure:    

  0,71 dm

3

/s (1.5 scfm) 

Maximum recommended flow: 28 dm

3

/s (60 scfm). Air 

flows above 28 dm

3

/s (60 scfm) create excessive air 

velocity, turbulence, and pressure losses. In addition, 

the fog produced by the lubricator will wet out on the 

pipe walls and will not be carried by the compressed 

air to the point of application.

Typical flow with 6,3 bar (90 psig) inlet pressure and 0,5  

bar(7 psig) pressure drop:

    Oil-Fog models: 75 dm

3

/s (158 scfm)

    Micro-Fog models: 65 dm

3

/s (138 scfm)

Nominal bowl size: 0,1 litre (3.5 fluid ounce)

Manual drain connection: 1/8"

Materials:

  Body: Aluminum

 Bowl:

    Transparent: Polycarbonate

    Transparent with guard: Polycarbonate, steel guard

    Metal: Aluminum 

  Metal bowl liquid level indicator lens: Transparent  

  nylon 

Sight-Feed dome: Transparent nylon

  Elastomers: Neoprene and nitrile

REPLACEMENT ITEMS

Service kit (includes items circled on 

  exploded view) ...........................................................4382-600

Liquid level lens kit (43, 45, 46, 47) ..........................4380-020

Manual drain (18, 19, 20) ..................................................619-50

INSTALLATION

1. Shut-off air pressure. Install lubricator in air line -

 

l

  vertically (reservoir down),

 

l

  with air flow in direction of arrow on body,

 

l

  downstream of filters and regulators

 

l

  upstream of cycling valves,

 

l

  as close as possible to the device being lubricated,

 

l

  Oil-Fog Models - Not more than 5,2m (15 feet) from  

  the device being lubricated, and at the same height 

or   higher than the device.

2. Connect piping to proper ports using pipe thread 

sealant on male threads only. Do not allow sealant to 

enter interior of unit.

3. Push reservoir, or reservoir with guard, into body and 

turn fully clockwise before pressurizing.

RECOMMENDED LUBRICANTS

Fill reservoir with a good quality, light, misting type oil 

for compressed air tools.  See Norgren publication N/

AL.8.900.935. Fill to maximum fill line on transparent 

reservoirs. Oil level must always be visible in lens on 

metal reservoirs. DO NOT OVERFILL.

FILL RESERVOIR (OIL-FOG LUBRICATORS)

Remove fill plug (2), add oil, and reinstall fill plug. Fill 

plug can be removed and oil added without shutting off 

air pressure to the lubricator.
NOTE: Oil fill plug (2) seals easily.  Tighten finger-tight 

only.

L73C/MExpldView08/97

49

1

6

7

8

9

2

3

4

17

27

36

46

44

43

47

39

38

41

42

30

29

32

28

33

34

35

20

19

22

18

23

31

33A

21

23A

40

42A

51

50

52

53

54

55

5

45

48

24

25

26

37

Micro-Fog® and Oil-Fog

Tool Lubricators

L73  *  -  *  *  *  -  *  *  *

Thread Form

A .... PTF

B .... ISO Rc taper

G ... ISO G parallel

Bowl

D ... Metal with plastic liquid level 

indicator

P .... Transparent with guard

R .... Metal with Pyrex liquid level indicator

Options

N ... None

P .... Pyrex sight-feed dome

Q ... Quick fill nipple

Drain

E .... Closed bottom

Q ... Manual, 1/4 

turn

Air Flow Direction

P .... Uni-directional

Type

C .... Oil-Fog

M ... Micro-Fog

Port

2 .... 1/4"

3 .... 3/8"

4 .... 1/2"

 

IM-180.400.01

 (9/98)

 

Supersedes 4/98

a subsidiary of IMI plc

© Norgren 1998

T .... Transparent

Отзывы: