background image

18

OUTDOOR

F

AN MO

TO

R

R

C

CC

C

H

F

DU

AL

CA

PA

CIT

OR 

(SINGLE PHASE)

FIELD SUPP

LY

L1

GRD

L2

GR

OUNDING

SCREW

C

S

T1

T2

L1

L2

CON

TA

CT

OR

R

COMPRESSOR

Y2 IN

FA

N2

CCH2

CCH1

W2 IN

Y1 IN

C

R

HO

T1

HO

T2

(24V COM)

OUTDOOR

   

TEMP

Y1 OU

T

RV

1

O

LP

1

LP

2

HP

1

HP

2

S

CC

DEFR

OST CONT

RO

L

BO

ARD

BLA

CK

      

YELLO

W/ 

YELLO

W BL

AC

K

BLA

CK/

BLA

CK 

WHITE

ORANGE

BLUE

COIL#1

 TEMP

RV

2

CCH

RV

S

HPS

COIL SENSOR

HGBP

LPS

AMB SENSOR

YR

OC

EW

2

THERMOST

AT

FA

N1

W2 OU

T

Y2 OU

T

RED/RED BL

AC

K

BLA

CK

BLA

CK

BLA

CK

YELLOW

BLA

CK

BLA

CK

BLACK

CC

Y2 IN

FA

N1

FA

N2

CCH2

CCH1

W2 IN

Y1 IN

C

R

HO

T1

HO

T2

           (24V COM)

OUTDOOR

    

TEMP

Y1 OU

T

RV

1

O

LP

1

LP

2

HP1

HP2

COIL#1

 TEMP

RV

2

Split System Heat Pump (Outdoor Section)

Single Phase

WIRING DIA

GRAM

NO

TES:

1.

 Disconnect all po

wer bef

ore servicing.

2.

 For suppl

y connections use copper conducto

rs

 on

ly

.

3.

 Not suitable on systems that e

xceed 150 v

olts to gr

ound

4.

 For replacement wires use conductor

s suitable f

or 105˚ C.

5.

 For ampacities and o

ver

current pr

otection

see unit rating plate

.

6.

 Connect to 24 v

ac/40v

a/c

lass 2 cir

cuit

 See furnace/air handler

    installation instructions f

or contr

ol cir

cuit and optional 

    rela

y/transf

ormer kits.

1.

 Couper le courant 

av

ant de faire letretien.

2.

 Empl

oy

ez uniquement des conducteu

rs

 en cuivre

.

3.

 Ne con

vient pas aux installations de plus de 150 v

olt a la terr

e.

711316A

04/13

FIELD 

WIRING

LEGEND:

LO

VO

LT

AG

E

HIGH 

VO

LT

AG

E

DU

AL CA

PA

CI

TO

R

H

C

F

COMPRESSOR

OUTDOOR F

AN MO

TO

R

R

C

S

L1

T1

L2

T2

DEFR

OST CONT

RO

L BO

ARD 

208/230V

R

C

S

CCH

RV

S

HPS

LPS

HGBP

COIL SENSOR

AMB SENSOR

YR

OC

EW

2

THERMOST

AT

AMB SENSOR - Ambient Sensor

CC - Contactor Coil

CCH - Crankcase Heater

HPS - High Pressure Switch

HGBP - Hot Gas By P

ass 

Va

lve

LPS - Lo

w Pressure Switc

h

R

VS - Re

ver

sing 

V

alve Solenoid

* HARD ST

AR

T KIT (OPTIONAL)

W2 OU

T

Y2 OU

T

ST

AR

 CA

PA

CIT

OR*

ST

AR

T RELA

Y*

5

2

1

YELLOW

BLA

CK

Figure 11. Wiring Diagram for 3.5 - 5 Ton Models 

Equipped with Low Pressure Switch

Содержание T4BD-042 Series

Страница 1: ...n how to operate and maintain the equipment for the life of the product Safety should always be the deciding factor when installing this product and using common sense plays an important role as well...

Страница 2: ...orotherhazardous conditions which may result in personal injury or property damage Installation of equipment may require brazing operations Installer must comply with safety codes andwearappropriatesa...

Страница 3: ...iled immediately with the carrier Pleaseconsultyourdealerformaintenanceinformation and availability of maintenance contracts Please read all instructions before installing the unit Locating the Heat P...

Страница 4: ...dryer is provided with the unit and must be installedintheliquidlineofthesystem Iftheinstallation replaces a system with a filter dryer already present in the liquid line the filter dryer must be rep...

Страница 5: ...y andtherestrictororifice whilebeingcarefulnottoscratch either part Carefully remove the restrictor orifice from the valve body See Figure 3 page 4 3 Check the actual size of the new orifice NOTE The...

Страница 6: ...Diagnostics Module Select Models Only The CoreSenseTM Diagnostics Module Figure 5 page 7 is a breakthrough innovation for troubleshooting heatpumpandairconditioningsystemfailures Themodule installs ea...

Страница 7: ...tart Check List Verify the unit is level and has sufficient clearances for unobstructed airflow Verify the outdoor coil and top of the unit are free from obstructions and debris and all equipment acce...

Страница 8: ...2 sec and does not start within 35 sec 10x consecutive Red Flash4 Yellow Off Code5 Yellow Flash 5 Compressor moderate run trip Compressor runs for 15 min to 18 hrs followed by a compressor trip lastin...

Страница 9: ...Data sheet for additional charging information Outdoor units with non AHRI listed indoor coils are not recommended and deviations from rated airflows or non listedcombinationsmayrequiremodificationtot...

Страница 10: ...ange of operation Reference the charts to determine the ideal amount of sub cooling for a given liquid pressure Units charged to other values will not perform at the rated unit efficiency EER or rated...

Страница 11: ...below the curve T4BD 048KA Charging Chart Cooling Figure 7 Charging Chart for 4 Ton Units TXV Matches 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600 75 80 85 90 95...

Страница 12: ...ring wet bulb temperatures are lower than design 1 All pressures are listed in psig and all temperatures in F 2 Discharge temperatures greater than charted values indicate an undercharged system 3 Dis...

Страница 13: ...LIQ PRESS DIS TEMP LIQ PRESS DIS TEMP 121 244 135 123 245 135 267 141 125 246 135 268 141 290 147 127 247 136 269 142 291 147 313 154 129 248 136 270 142 292 148 314 154 336 160 131 271 142 293 148 31...

Страница 14: ...the liquid line temperature on the inlet and outlet of the filter dryers If it is the factory dryer and in good condition there should be no temperature difference If the temperature difference is lar...

Страница 15: ...0 221 232 105 45 239 250 112 60 257 268 120 75 275 286 127 90 288 299 136 105 314 325 146 121 339 350 155 31 228 239 103 46 245 256 110 61 261 272 118 76 278 289 125 91 295 306 133 106 321 332 141 122...

Страница 16: ...ot suitable on systems that exceed 150 volts to ground 4 For replacement wires use conductors suitable for 105 C 5 For ampacities and overcurrent protection see unit rating plate 6 Connect to 24 vac 4...

Страница 17: ...0 volts to ground 4 For replacement wires use conductors suitable for 105 C 5 For ampacities and overcurrent protection see unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace air h...

Страница 18: ...ts to ground 4 For replacement wires use conductors suitable for 105 C 5 For ampacities and overcurrent protection see unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace air handle...

Страница 19: ...19...

Страница 20: ...NO INSTALLER NAME CITY________________________ STATE_________________ Has the owner s information been reviewed with the customer YES NO Has the Literature Package been left with the unit YES NO 7096...

Отзывы: