important SaFEtY inFormation
please read all instructions before servicing this
equipment. Pay attention to all safety warnings and any
other special notes highlighted in the manual. Safety
markings are used frequently throughout this manual to
designate a degree or level of seriousness and should not
be ignored. WarninG indicates a potentially hazardous
situation that if not avoided, could result in personal injury
or death. CaUtion indicates a potentially hazardous
situation that if not avoided, may result in minor or moderate
injury or property damage.
WarninG:
propoSition 65 WarninG: this product
contains chemicals known to the state of
California to cause cancer, birth defects or other
reproductive harm.
WarninG:
read the installation instructions supplied
with the furnace / air handler. always observe
all safety requirements outlined in this manual
and on the furnace/air handler markings before
installing the coil.
inStallation inStrUCtionS
Split SYStEm UnCaSED rEplaCEmEnt inDoor CoilS
WarninG:
improper installation, service, adjustment,
or maintenance may cause explosion, fire,
electrical shock or other hazardous conditions
which may result in personal injury or property
damage. Unless otherwise noted in these
instructions, only factory authorized kits or
accessories may be used with this product.
GEnEral inFormation
These uncased replacement coils are designed for upflow,
downflow, or horizontal applications.
• Check the coils orifice size and confirm that it’s suitable
for application with the intended outdoor unit. Depending
on application, additional installer supplied orifice or
TXV may be required.
• Verify that the air delivery of the furnace/air handler is
adequate to handle the static pressure drop of the coil,
filter, and duct work.
• If precise forming of refrigerant lines is required, a
copper tubing bender is recommended. Avoid sharp
bends and contact of the refrigerant lines with metal
surfaces.
• Refrigerant lines should be wrapped with pressure
sensitive neoprene or other suitable material where
they pass against sharply edged sheet metal.
• Horizontal installations require a horizontal drain pan
kit to be installed. See Table 1 (page 3) for part number.