background image

22

Refrig

erant Char

ging Char

ts f

or Heating Mode of Operation

14 SEER Split System Heating Char

ts

048K

O

UT

DO

O

R T

E

M

P

E

RA

T

URE

  (

DE

G

. F

)

0

10

20

30

40

50

60

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Pr

e

s

s

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

P

re

ss.

 Pre

ss.

T

em

p.

P

re

ss.

 Pre

ss.

T

em

p.

P

re

ss.

 Pre

ss.

T

em

p.

P

re

ss.

 Pre

ss.

T

em

p.

37

217

126

50

237

133

62

256

141

75

276

148

88

283

158

101

302

170

114

322

183

38

224

124

51

243

131

63

261

139

76

279

146

89

290

155

102

309

166

115

329

177

39

231

122

52

248

129

64

266

137

77

283

144

90

297

152

103

316

161

116

336

170

40

238

120

53

254

127

65

270

135

78

287

142

91

304

149

104

323

157

117

343

164

41

245

118

54

260

125

66

275

133

79

290

140

92

311

146

105

330

152

118

350

158

42

252

116

55

266

123

67

280

131

80

294

138

93

318

143

106

337

148

119

357

152

43

259

114

56

272

121

68

285

129

81

298

136

94

325

141

107

344

143

120

364

146

060K

O

UT

DO

O

R T

E

M

P

E

RA

T

URE

  (

DE

G

. F

)

0

10

20

30

40

50

60

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Pr

e

s

s

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

P

re

ss.

 Pre

ss.

T

em

p.

P

re

ss.

 Pre

ss.

T

em

p.

P

re

ss.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

35

227

152

46

249

159

57

272

166

68

294

173

79

304

182

88

324

192

97

345

202

36

234

150

47

255

157

58

276

164

69

298

171

80

311

179

89

331

187

98

352

195

37

241

148

48

261

155

59

281

162

70

301

169

81

318

176

90

338

183

99

359

189

38

248

146

49

267

153

60

286

160

71

305

167

82

325

173

91

345

178

100

366

183

39

255

144

50

273

151

61

291

158

72

309

165

83

332

170

92

352

174

101

373

177

40

262

142

51

279

149

62

296

156

73

312

163

84

339

168

93

359

169

102

380

171

41

269

140

52

285

147

63

300

154

74

316

161

85

346

165

94

366

165

103

387

165

Содержание DT4BE

Страница 1: ...t eliminate your problem call your servicing contractor Heat Pump Principle of Operation USER S INFORMATION 5 4 1 2 3 6 5 4 3 2 1 6 SUMMER COOLING 1 Indoor air enters the air handler section 2 Cold he...

Страница 2: ...2...

Страница 3: ...and ice to melt After the snow and ice have melted some steam may rise from the outdoor unit as the warm coil causes some melted frost to evaporate Figure 1 Typical Thermostat OPERATING INSTRUCTIONS T...

Страница 4: ...re the electrical power to the outdoorunitandthefurnace airhandler is disconnected before doing the following recommended maintenance 1 Regularly a Clean or replace the indoor air filter at the start...

Страница 5: ...operational checkout of the equipment BrazingOperations Installationofequipment may require brazing operations Safety codes must be complied with Safety equipment e g safety glasses work gloves fire e...

Страница 6: ...installationreplaces a system with a filter dryer already present in the liquid line the filter dryer must be replaced with the one supplied with the unit The filter dryer must be installed in strict...

Страница 7: ...power to the outdoor unit ensure that the unit has been properly and securely grounded and that power supply connections have been made at both the facility power interface and outdoor unit Outdoor Un...

Страница 8: ...stat Green Red Brown G R W2 Orange Black O Y R C Air Handler Heat Pump OD Section Typical Heat Pump with Standard Air Handler W2 C W NOTE Jumper betweenW2 and E is required when no OD T Stat is used F...

Страница 9: ...Red White G R Black O Y R C Air Handler Heat Pump OD Section Typical Heat Pump with Outdoor Thermostat and Air Handler W2 C W E A typical installation with a heat pump thermostat air handler and heat...

Страница 10: ...tection The Comfort AlertTM module is a monitoring device and cannot control or shut down other devices LED Description See Figure 2 POWERLED Green indicatesvoltageispresent at the power connection of...

Страница 11: ...he unit is being installed Example 1 Dry climate of Southern Arizona A 90 minute setting is recommended Example 2 Moist climate of Seattle Washington A 30 minute setting is recommended To set the cycl...

Страница 12: ...if voltage at disconnect is low Excessive liquid refrigerant in compressor Compressor bearings are seized ALERT Flash Code 4 Yellow LED Locked Rotor Run capacitor has failed Low line voltage contact...

Страница 13: ...ermanently the defrost cycle will become inoperable Miswired Module Indication Recommended Troubleshooting Action Green LED is not on module does not power up Determine if both R C module terminals ar...

Страница 14: ...the checkout procedures supplied with the equipment Adjustment of Refrigerant Charge CAUTION Split system heat pump equipment contains liquid and gaseous refrigerantunderpressure Adjustment of refrige...

Страница 15: ...90 95 100 105 110 115 120 125 130 Liquid Temperature F Liquid P res s ure ps ig Add refrigerant when below curve Remove refrigerant when above curve 2 Ton Heat Pump TXV Cooling Charging Chart 200 225...

Страница 16: ...90 95 100 105 110 115 120 125 130 Liquid Temperature F Liquid P res s ure ps ig Add refrigerant when below curve Remove refrigerant when above curve 3 Ton Heat Pump TXV Cooling Charging Chart 200 225...

Страница 17: ...90 95 100 105 110 115 120 125 130 Liquid Temperature F Liquid P res s ure ps ig Add refrigerant when below curve Remove refrigerant when above curve 4 Ton Heat Pump TXV Cooling Charging Chart 200 225...

Страница 18: ...m Cooling Charts 5 Ton Heat Pump TXV Cooling Charging Chart 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 70 75 80 85 90 95 100 105 110 115 120 125 130 Liquid Temperature F Liquid P res...

Страница 19: ...Disch Suc Liquid Disch Suc Liquid Disch Suc Liquid Disch Suc Liquid Disch Suc Liquid Disch Suc Liquid Disch Press Press Temp Press Press Temp Press Press Temp Press Press Temp Press Press Temp Press P...

Страница 20: ...58 272 114 73 299 122 87 327 129 103 368 141 122 406 157 140 443 174 45 251 105 59 278 112 74 304 120 88 331 127 104 375 138 123 413 153 141 450 167 030K OUTDOOR TEMPERATURE DEG F 0 10 20 30 40 50 60...

Страница 21: ...55 256 113 70 279 119 85 301 126 100 334 136 116 360 148 132 386 160 41 241 104 56 262 111 71 284 117 86 305 124 101 341 133 117 367 144 133 393 154 042K OUTDOOR TEMPERATURE DEG F 0 10 20 30 40 50 60...

Страница 22: ...52 116 55 266 123 67 280 131 80 294 138 93 318 143 106 337 148 119 357 152 43 259 114 56 272 121 68 285 129 81 298 136 94 325 141 107 344 143 120 364 146 060K OUTDOOR TEMPERATURE DEG F 0 10 20 30 40 5...

Страница 23: ...23...

Страница 24: ...PLEASE LEAVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOWNER 708695B Replaces 708695A Specifications illustrations subject to change without notice or incurring obligations O Fallon MO Printed in U...

Отзывы: