background image

20

Refrig

erant Char

ging Char

ts f

or Heating Mode of Operation

14 SEER Split System Heating Char

ts

024K

O

UT

DO

O

R T

E

M

P

E

RA

T

URE

  (

DE

G

. F

)

0

10

20

30

40

50

60

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Pr

e

s

s

 Pre

ss.

T

em

p.

P

re

ss.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

P

re

s

s

.

 Pre

ss.

T

em

p.

39

209

117

53

242

124

68

276

132

82

309

139

98

333

155

117

371

180

135

408

204

40

216

115

54

248

122

69

280

130

83

312

137

99

340

153

118

378

175

136

415

198

41

223

113

55

254

120

70

285

128

84

316

135

100

347

150

119

385

171

137

422

192

42

230

111

56

260

118

71

290

126

85

320

133

101

354

147

120

392

166

138

429

186

43

237

109

57

266

116

72

295

124

86

323

131

102

361

144

121

399

162

139

436

180

44

244

107

58

272

114

73

299

122

87

327

129

103

368

141

122

406

157

140

443

174

45

251

105

59

278

112

74

304

120

88

331

127

104

375

138

123

413

153

141

450

167

030K

O

UT

DO

O

R T

E

M

P

E

RA

T

URE

  (

DE

G

. F

)

0

10

20

30

40

50

60

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Su

c

.

Li

qui

d

D

isch

.

Pr

e

s

s

 Pre

ss.

T

em

p.

P

re

ss.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

Pr

e

s

s

.

 Pre

ss.

T

em

p.

P

re

s

s

.

 Pre

ss.

T

em

p.

36

198

114

51

237

124

65

276

135

80

315

145

95

343

162

110

382

183

126

422

205

37

205

112

52

243

122

66

281

133

81

319

143

96

350

159

111

389

179

127

429

199

38

212

110

53

249

120

67

286

131

82

322

141

97

357

156

112

396

174

128

436

193

39

219

108

54

255

118

68

290

129

83

326

139

98

364

153

113

403

170

129

443

187

40

226

106

55

261

116

69

295

127

84

330

137

99

371

150

114

410

165

130

450

181

41

233

104

56

266

114

70

300

125

85

333

135

100

378

147

115

417

161

131

457

174

42

240

102

57

272

112

71

305

123

86

337

133

101

385

145

116

424

156

132

464

168

Содержание DT4BE

Страница 1: ...t eliminate your problem call your servicing contractor Heat Pump Principle of Operation USER S INFORMATION 5 4 1 2 3 6 5 4 3 2 1 6 SUMMER COOLING 1 Indoor air enters the air handler section 2 Cold he...

Страница 2: ...2...

Страница 3: ...and ice to melt After the snow and ice have melted some steam may rise from the outdoor unit as the warm coil causes some melted frost to evaporate Figure 1 Typical Thermostat OPERATING INSTRUCTIONS T...

Страница 4: ...re the electrical power to the outdoorunitandthefurnace airhandler is disconnected before doing the following recommended maintenance 1 Regularly a Clean or replace the indoor air filter at the start...

Страница 5: ...operational checkout of the equipment BrazingOperations Installationofequipment may require brazing operations Safety codes must be complied with Safety equipment e g safety glasses work gloves fire e...

Страница 6: ...installationreplaces a system with a filter dryer already present in the liquid line the filter dryer must be replaced with the one supplied with the unit The filter dryer must be installed in strict...

Страница 7: ...power to the outdoor unit ensure that the unit has been properly and securely grounded and that power supply connections have been made at both the facility power interface and outdoor unit Outdoor Un...

Страница 8: ...stat Green Red Brown G R W2 Orange Black O Y R C Air Handler Heat Pump OD Section Typical Heat Pump with Standard Air Handler W2 C W NOTE Jumper betweenW2 and E is required when no OD T Stat is used F...

Страница 9: ...Red White G R Black O Y R C Air Handler Heat Pump OD Section Typical Heat Pump with Outdoor Thermostat and Air Handler W2 C W E A typical installation with a heat pump thermostat air handler and heat...

Страница 10: ...tection The Comfort AlertTM module is a monitoring device and cannot control or shut down other devices LED Description See Figure 2 POWERLED Green indicatesvoltageispresent at the power connection of...

Страница 11: ...he unit is being installed Example 1 Dry climate of Southern Arizona A 90 minute setting is recommended Example 2 Moist climate of Seattle Washington A 30 minute setting is recommended To set the cycl...

Страница 12: ...if voltage at disconnect is low Excessive liquid refrigerant in compressor Compressor bearings are seized ALERT Flash Code 4 Yellow LED Locked Rotor Run capacitor has failed Low line voltage contact...

Страница 13: ...ermanently the defrost cycle will become inoperable Miswired Module Indication Recommended Troubleshooting Action Green LED is not on module does not power up Determine if both R C module terminals ar...

Страница 14: ...the checkout procedures supplied with the equipment Adjustment of Refrigerant Charge CAUTION Split system heat pump equipment contains liquid and gaseous refrigerantunderpressure Adjustment of refrige...

Страница 15: ...90 95 100 105 110 115 120 125 130 Liquid Temperature F Liquid P res s ure ps ig Add refrigerant when below curve Remove refrigerant when above curve 2 Ton Heat Pump TXV Cooling Charging Chart 200 225...

Страница 16: ...90 95 100 105 110 115 120 125 130 Liquid Temperature F Liquid P res s ure ps ig Add refrigerant when below curve Remove refrigerant when above curve 3 Ton Heat Pump TXV Cooling Charging Chart 200 225...

Страница 17: ...90 95 100 105 110 115 120 125 130 Liquid Temperature F Liquid P res s ure ps ig Add refrigerant when below curve Remove refrigerant when above curve 4 Ton Heat Pump TXV Cooling Charging Chart 200 225...

Страница 18: ...m Cooling Charts 5 Ton Heat Pump TXV Cooling Charging Chart 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 70 75 80 85 90 95 100 105 110 115 120 125 130 Liquid Temperature F Liquid P res...

Страница 19: ...Disch Suc Liquid Disch Suc Liquid Disch Suc Liquid Disch Suc Liquid Disch Suc Liquid Disch Suc Liquid Disch Press Press Temp Press Press Temp Press Press Temp Press Press Temp Press Press Temp Press P...

Страница 20: ...58 272 114 73 299 122 87 327 129 103 368 141 122 406 157 140 443 174 45 251 105 59 278 112 74 304 120 88 331 127 104 375 138 123 413 153 141 450 167 030K OUTDOOR TEMPERATURE DEG F 0 10 20 30 40 50 60...

Страница 21: ...55 256 113 70 279 119 85 301 126 100 334 136 116 360 148 132 386 160 41 241 104 56 262 111 71 284 117 86 305 124 101 341 133 117 367 144 133 393 154 042K OUTDOOR TEMPERATURE DEG F 0 10 20 30 40 50 60...

Страница 22: ...52 116 55 266 123 67 280 131 80 294 138 93 318 143 106 337 148 119 357 152 43 259 114 56 272 121 68 285 129 81 298 136 94 325 141 107 344 143 120 364 146 060K OUTDOOR TEMPERATURE DEG F 0 10 20 30 40 5...

Страница 23: ...23...

Страница 24: ...PLEASE LEAVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOWNER 708695B Replaces 708695A Specifications illustrations subject to change without notice or incurring obligations O Fallon MO Printed in U...