Maintenance
5‐5
Part 7192568-03
E
2020 Nordson Corporation
Level Sensors
WARNING:
Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
1. Remove the cable from the sensor.
2. Remove the faulty sensor.
3. Screw in the new sensor, ensuring there are 1 or 2 threads into the hopper.
4. Connect the cable to the new sensor.
5. Place hand in front of the sensor to ensure the controller screen reads the
sensor.
Sieve Screen
WARNING:
Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
1. Open the control panel and shut off the generator.
2. Disengage the lid latch and open the lid.
3. Remove the damaged sieve screen from the hopper.
4. Disconnect the convertor.
5. Connect the convertor to the new sieve screen.
6. Place the new sieve screen onto the hopper.
7. Close and lock the lid by engaging the lid latch.