Nordson Spectra 30 Скачать руководство пользователя страница 1

Instruction Sheet

P/N 1124826

11/2015

Spectra 30 Control Board

Kit - P/N 1124812

This instruction sheet describes how to replace the control board in the

Spectra 30 pattern controller

WARNING:

Risk of personal injury or equipment damage! Refer to

the safety information provided in the melter manual before servicing

the melter. Failure to comply with the safety information provided can

result in personal injury, including death.

Required Tools:

Small Phillips screwdriver

M6 socket

Large flat screwdriver

Control Board

NOTE:

The previous control board kit, Part Number 1123818 with control board, Part Number 1122026, has been discontinued. However, if the

customer has the previous boards, they need to use the following items provided in this new kit, Part Number 1124812:

– Water shield

– Wiring diagram tag

– Terminal blocks

Continue

Removing the Control Board

Allow only personnel with appropriate training and experience to operate or

service the equipment. The use of untrained or inexperienced personnel to

operate or service the equipment can result in injury, including death, to

themselves and others, and damage to the equipment.

Warning:

1.

Turn off the pattern controller switch and disconnect the input power supply.

2.

Unfasten the four captive screws (see

a

in Figure 1) to remove the pattern

controller front cover.

a

Figure 1

a: Four captive screws

b

Figure 2

a

3.

Remove the display ribbon cable (see

c

in Figure 2) by lifting up the cable

connector lock tabs and carefully pulling it out.

c

d

a: Touch screen panel

b: Standoffs

c: Ribbon cable

d: Two captive screws

Отзывы: