Model SCH-1 Heater
4
E
1999 Nordson Corporation
All rights reserved
108 151D
Issued 8/99
Manual 12-11
To avoid a fire or explosion, follow these instructions.
S
Ground all conductive equipment in the spray area. Use only
grounded air and fluid hoses. Check equipment and workpiece
grounding devices regularly. Resistance to ground must not exceed
one megohm.
S
Shut down all equipment immediately if you notice static sparking or
arcing. Do not restart the equipment until the cause has been
identified and corrected.
S
Do not smoke, weld, grind, or use open flames where flammable
materials are being used or stored.
S
Do not heat materials to temperatures above those recommended by
the manufacturer. Make sure heat monitoring and limiting devices are
working properly.
S
Provide adequate ventilation to prevent dangerous concentrations of
volatile particles or vapors. Refer to local codes or your material
MSDS for guidance.
S
Do not disconnect live electrical circuits while working with flammable
materials. Shut off power at a disconnect switch first to prevent
sparking.
S
Know where emergency stop buttons, shutoff valves, and fire
extinguishers are located. If a fire starts in a spray booth,
immediately shut off the spray system and exhaust fans.
S
Shut off electrostatic power and ground the charging system before
adjusting, cleaning, or repairing electrostatic equipment.
S
Clean, maintain, test, and repair equipment according to the
instructions in your equipment documentation.
S
Use only replacement parts that are designed for use with original
equipment. Contact your Nordson representative for parts
information and advice.