Description 

See Figure 1.  The Electric Drum/Pail Level indicators
use proximity sensors to monitor the distance between
the bottom of the follower plate and the base surface of
the bulk unloader frame.

The Empty Drum/Pail Level Indicator sends an
Empty Level signal to the controller when the bulk
unloader crossover moves in front of the empty level
proximity sensor.

The Low and Empty Drum/Pail Level Indicator sends a
Low Level signal to the controller when the crossover
moves in front of the low level proximity sensor.  The
target plate prevents the low level proximity sensor
circuit from opening during the downward movement of
the crossover.  When the crossover moves in front of the
empty level proximity sensor, the indicator sends an
Empty Level signal to the controller.

Four Drum/Pail Level Indicators are available:

S

Drum/Pail Empty
(18 mm and 30 mm Proximity Sensors)

S

Drum/Pail Low and Empty
(18 mm and 30 mm Proximity Sensors)

Repair 

Repairs consist of replacing the proximity sensors and
setting the Low and Empty Level signals.

WARNING:  Allow only qualified personnel to
perform the following tasks.  Follow the safety
instructions in this document and all other
related documentation.

CAUTION:  To prevent damage to equipment,
personnel performing these procedures must
know how to safely operate the elevator control
valve on the Rhino SD2/XD2 bulk unloader.

NOTE:  Read and understand these procedures before
performing repairs.  If necessary, contact a local Nordson
representative regarding repairs to this equipment.

EMPTY DRUM/LEVEL INDICATOR

CROSSOVER

LOW LEVEL
PROXIMITY SENSOR

EMPTY LEVEL
PROXIMITY SENSOR

TARGET PLATE

LOW AND EMPTY DRUM/LEVEL INDICATOR

EMPTY LEVEL
PROXIMITY SENSOR

CROSSOVER

Figure 1

Rhino SD2/XD2 Drum/Pail Level Indicators

Содержание Rhino SD2

Страница 1: ...r sends an Empty Level signal to the controller Four Drum Pail Level Indicators are available S Drum Pail Empty 18 mm and 30 mm Proximity Sensors S Drum Pail Low and Empty 18 mm and 30 mm Proximity Se...

Страница 2: ...the follower plate to test the Low and Empty signals Set the Low and Empty Level Signals Refer to Table 1 The Low and Empty Level signals are factory set If desired adjust the proximity sensor to chan...

Страница 3: ...ensor if necessary 6 Using the Rhino SD2 XD2 bulk unloader elevator control valve raise and lower the follower plate to test the Low and Empty signals 7 If removed install the hold down shoes 1 onto t...

Страница 4: ...NG SPACER HEIGHT 1 5 IN 7 50 LOW SETTING SPACER HEIGHT 7 5 IN LOW SETTING SPACER HEIGHT 4 5 IN LARGE FRAME WITH PAIL FOLLOWER PLATE AND HOLD DOWN MODULE LARGE FRAME WITH DRUM FOLLOWER PLATE EMPTY SETT...

Страница 5: ...e drum empty 18 mm 1 1 1070398 S Bracket 1 2 1042530 S Label 1 3 985112 S Rivet 2 4 332947 S Switch proximity 30 mm FOR USE ON LEVEL INDICATOR 1070334 1 4 223492 S Switch proximity 18 mm FOR USE ON LE...

Страница 6: ...c Drum Pail Level Indicators 6 Part 1077746A E 2007 Nordson Corporation Low and Empty Level Indicator See Figure 6 and the following parts list 4 5 6 7 8 10 1 2 3 15 14 13 12 9 11 11 Figure 6 Low and...

Страница 7: ...proximity 30 mm FOR USE ON LEVEL INDICATOR 1070337 2 5 345754 S Screw socket 10 24 x 0 50 grade 8 4 6 983079 S Washer lock 10 4 7 983123 S Washer flat 4 8 1044341 S Plate adjustable M18 FOR USE ON LE...

Страница 8: ...ators 8 Part 1077746A E 2007 Nordson Corporation Notes Issued 7 07 Original copyright date 2007 Nordson the Nordson logo and Rhino are registered trademarks of Nordson Corporation All other trademarks...

Отзывы: