Appendix B, Non-Wizard Setup Procedures
All setup and calibration procedures are guided by the Robot Initial Setup wizard, which should be used after any
system change, including tip change-out. However, the procedures in this appendix can be performed individually
and are provided here for your reference as needed.
Setting the Camera Scale
PREREQUISITES
The system is fully installed (including the dispensing valve) and includes fluid.
The bottom of the tip is lower than the bottom of the camera.
The workpiece is present on the fixture plate.
#
Click
Step
Reference Image
1
• Click the CAMERA tab.
2
• Jog the camera to a point of reference that
is located on the lower right corner of the
workpiece.
• Bring the image into focus. Refer to
“Camera” on page 16 as needed for
instructions on focusing the camera.
3
>
• Click the CAMERA tab and then click
SCALE.
The Scale window opens.
NOTE:
When the camera views an object, it
converts the pixels to a true measurement.
For the camera to make this conversion
accurately, you must “teach” the camera
what the size of an object is in comparison
to pixels per inch by setting the camera
scale.
4
• Choose a point of reference on the
workpiece and jog the camera so that the
reference point is located in the lower right
quadrant of the camera screen, then click
the point.
5
• Jog the camera again until the same
reference point is located in the upper left
quadrant of the camera screen, then click
the point.
The camera scale is now set.