Tank
Temperature
Enable/Disable
Set Point
Manifold
Hose 1
Applicator 1
OLED User Interface
28
Part 1128351_02
E
2020
Nordson Corporation
Managing Heated Zones
There are two types of heated zones:
S
Internal Zones
: Tank and the manifold
S
External Zones
: Connected hoses and applicators
Enabling/Disabling and Changing Zone Set Point
Temperatures
1. Navigate and select the zone you want to enable/disable or change its
set point temperature and press
>
on the Navigation pad.
2. Do the following to continue:
S
To Enable/Disable an external zone - Press the
on the Navigation pad
to toggle the zone to Enable or Disable. When done, press the
<
on the
Navigation pad to return to the previous screen.
S
To change the set point temperature, press the Up/Down keys on the
Navigation pad to select the zone you want to change its set point
temperature, then press
>
and enter the set point temperature you want.
When done, press the
.
Zone
Default
Minimum
Maximum
Internal Zones
177
_
C
(351
_
F)
40
_
C
(100
_
F)
204
_
C
(400
_
F)
External Zones
177
_
C
(351
_
F)
40
_
C
(100
_
F)
232
_
C
(450
_
F)
NOTES:
S
By default, internal zones are
enabled,
and all external zones are
disabled.
S
Select
Global Set Point
to make all zones (enabled or disabled) the
same set point temperature.
S
Internal zones (tank and manifold) cannot be disabled. You can only
change their set point temperatures.
S
Although there are two internal zones (tank and manifold), changing one
internal zone automatically changes the other. You cannot have two
different internal zone set point temperatures.