Starting the Melter
Before starting the melter for the first time, confirm that the melter is fully
installed, including any required inputs and outputs, hoses, and applicators.
By default, all connected hoses and applicators are disabled, and the Master
Heater control is Off. You can change this by navigating to
Home
screen
>
Temperature Settings > Global Settings
and enabling the
Heaters On
Upon Startup
option.
1. Switch the melter power to On. The melter performs a self-check. You will
see all the LEDs and indicators briefly illuminate. When done, the
Commissioning Wizard starts.
NOTE:
On subsequent melter power-up processes, the
Home
screen
appears after the melter completes its self-check.
Shutting Down the Melter
Shut down the melter when it will not be used for an extended period of time.
1. Switch the melter Off.
The Automatic Pressure Discharge (APD) valve relieves the hydraulic
pressure back to the tank.
2. Disable the applicators as follows:
S
Air‐operated applicators: Turn Off the air supply to the applicators.
S
Electric applicators: Turn Off the applicator driver, pattern controller,
or timer.