Nordson iDry
r
Series Induction Dryers
3
Part 1075452
−
04
E
2016 Nordson Corporation
Fire Safety
WARNING:
The iDry system is designed for use with water-based sealing
compounds only. It is not approved for used with solvent-based
compounds.
To avoid a fire or explosion, follow these instructions:
S
All equipment must be grounded and bonded to the building ground.
S
Do not heat materials to temperatures above those recommended.
Make sure heat monitoring and limiting devices are working properly.
S
Provide adequate ventilation to prevent dangerous concentrations of
volatile particles or vapors. Refer to local codes or your material MSDS
for guidance.
S
Do not disconnect live electrical circuits while working with flammable
materials. Shut off power at a disconnect switch first to prevent
sparking. Allow 10 minutes for all internal energy storage devices to
completely discharge.
S
Know where emergency stop buttons, shutoff valves, and fire
extinguishers are located.
S
Clean, maintain, test, and repair equipment according to the instructions
in your equipment documentation.
S
Use only replacement parts that are designed for use with original
equipment. Contact your Nordson representative for parts information
and advice.
Action in the Event of a Malfunction
If a system or any equipment in a system malfunctions, shut off the system
immediately and perform the following steps:
S
Disconnect and lock out system electrical power.
S
Identify the reason for the malfunction and correct it before restarting the
system.
Disposal
Dispose of equipment and materials used in operation and servicing in
accordance with applicable laws, regulations, or codes.