External Interlock Timer Setting (Optional)
The External Interlock timer starts when a run signal is received from the
customer line. If the motion sensor does not detect motion before the timer
expires, the alarm relay will change state and activate a customer-supplied
external alarm. The timer setting is dependent on line speed.
1. Touch the
RAMP/TIMER
button on the Navigation screen (Figure 16).
The Timer and Ramp Control screen appears (Figure 18).
2. Touch the
EXTERNAL INTERLOCK TIMER
field and set the desired
time with the keypad.
3. Touch
ENT
to save your setting.
External Interlock Activation
The External Interlock must be wired and activated before you can set the
timer. Refer to Installation for information on wiring. The following
procedure details the settings required to use the interlock.
1. Touch the
CONFIG
button on the Navigation screen (Figure 16). The
Option Setup screen appears. (This screen is password-protected by
default, contact your Nordson representative).
Figure 20 Option Setup Screen
2. Touch the
EXT INTERLOCK FAULT MODE
button to toggle the mode to
ON
.
3. Touch the
EXTERNAL RUN SIGNAL
button to toggle the mode to
MONITORED
.
4. Touch the
BACK
button to return to the Navigation screen.