Applicators
11
P/N 317091G
E
2011 Nordson Corporation
EP11 / EP 12
Lubricated or Non‐lubricated Compressed Air
CAUTION:
Control modules
EP 10 D
may be operated only with dry,
controlled and non‐lubricated compressed air.
NOTE:
The control module
EP 10
can be operated with either lubricated or
non‐lubricated compressed air.
Operating with Non‐lubricated Compressed Air
When an applicator is connected to a compressed air system in which the
compressed air has previously been lubricated, simply ceasing to lubricate
the air is not sufficient. The oil remaining in the compressed air supply will
reach the solenoid valves and the control modules and wash out the original
lubricant/oil from these parts, substantially decreasing the service life of the
units.
NOTE:
It must be ensured that the compressed air supply to the application
heads has been converted to absolutely non‐lubricated operation.
NOTE:
It must be ensured that no oil from a possibly defective compressor
may be permitted to penetrate the compressed air supply.
NOTE:
Nordson will assume no warranty/liability for damage resulting from
unpermitted, temporary lubrication.
Operating with Lubricated Compressed Air
The control module
EP 10
can also be operated with lubricated compressed
air.
NOTE:
Once the air has been lubricated, it must always be lubricated; the
lubricated compressed air will wash out the original lubricant on the solenoid
valves and the control modules.
Use only resin‐free, low‐viscosity silicon oil. Nordson recommends:
Oil
P/N
Klüber Unisilkon TK 002/100
253 700