© 2021 Nordson Corporation
4-5
Empty (No Powder) Programming
NOTE:
Programming the level sensor for Empty overwrites the values set for Full. If you
program the level sensor for Empty, be sure to also program it for Full.
1. Lower the lance assembly until the powder covers at least 25 mm (1 in.) of the level
sensor probe.
2. Raise the lance assembly so that the bottom of the level sensor probe is at least 25
mm (1 in.) away from the surface of the powder.
3. See Figure 4-2
. Press the programming button until the green LED flashes slowly,
then release it. When the green LED stops flashing and the yellow LED turns off, the
level sensor is programmed for Empty.
NOTE:
The green LED will flash slowly for 5 seconds, then start flashing quickly. If you
are still pressing the programming button when the green LED starts to flash quickly, you
will be programming the level sensor for Full instead of Empty. Repeat the procedure
from the beginning to program the level sensor for Empty, releasing the button while the
green LED is flashing slowly.
Full Programming
NOTE:
You can program the level sensor for Full as often as desired without overwriting
the Empty value.
1. Lower the lance assembly until the powder covers at least 25 mm (1 in.) of the level
sensor probe.
2. See Figure 4-2
. Press the programming button until the green LED flashes quickly,
then release the button.
The green LED flashes slowly at first, then after five seconds it flashes quickly. When
both the green and yellow LEDs are lit continuously, the full adjustment is complete.
Locking and Unlocking the Level Sensor
The level sensor can be locked to protect it from unauthorized adjustment.
NOTE:
The level sensor is shipped unlocked.
Task
Procedure
Locking
Press the programming button for 10 seconds. The green LED will
flash slowly for five seconds, then it will flash quickly.
When the green LED turns off, the level sensor probe is locked. When
the green LED turns back on continuously, the level sensor probe is
ready for operation.
Unlocking
Press the programming button for 10 seconds. After 10 seconds, all
LEDs turn off, indicating that the level sensor probe is unlocked.
Содержание Encore XL Powder
Страница 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Страница 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Страница 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Страница 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Страница 133: ...2021 Nordson Corporation 1607027 01 9 31 Parts 7 6 1 3 2 4 8 5 Figure 9 21 Sieve Parts Sieve with Angled Chute Shown...
Страница 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Страница 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Страница 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ...ON OFF...
Страница 154: ......