Operation
4-2
Part 1604858-01
E
2013 Nordson Corporation
Atomizing Air
(Classic)
Total Flow
(Smart Flow)
Select Charge
Mode Settings
KV/
μ
A Panel
KV/
μ
A Display
Selection
Smart Flow
Mode Indicator
Flow Air
(Classic)
Powder Flow Rate
(Smart Flow)
Enable/Disable
Trigger LED
Gun Controller Interface
Displays and LEDs
When the gun is triggered the Trigger LED lights.
When the controller is configured for Smart Flow mode, the Smart
Flow LED lights.
When the gun is triggered the actual kV or
μ
A output is displayed. When the
gun is not triggered the kV or
μ
A setpoint is displayed. The flow and
atomizing or total flow setpoints are always displayed.
Electrostatic Settings
Electrostatic output can be set in Select Charge mode, or in Custom or
Classic mode. Custom or Classic mode is chosen when the controller is
configured. Set the electrostatic output depending on the shape and type of
product being coated and the powder used.
Select Charge
r
Mode
The Select Charge modes are non-adjustable electrostatic settings. The
LEDs above the Select Charge mode buttons indicate the selected mode.
The Select Charge Modes and electrostatic setpoints are:
Recoat
100 kV, 15
μ
A
Metallics
50 kV, 50
μ
A
Deep Recesses
100 kV, 60
μ
A
NOTE:
Pressing the
+
or
−
keys have no effect when a Select Charge
mode is selected.
Содержание Encore LT Automatic
Страница 4: ...Change Record ii Part 1604858 01 E 2013 Nordson Corporation...
Страница 8: ...Table of Contents vi Part 1604858 01 E 2013 Nordson Corporation...
Страница 12: ...Safety 1 4 Part 1604858 01 E 2013 Nordson Corporation...
Страница 20: ...Description 2 8 Part 1604858 01 E 2013 Nordson Corporation...
Страница 34: ...System Setup 3 14 Part 1604858 01 E 2013 Nordson Corporation...
Страница 44: ...Operation 4 10 Part 1604858 01 E 2013 Nordson Corporation...
Страница 63: ...Wiring Diagrams 7 1 Part 1604858 01 E 2013 Nordson Corporation Section 7 Wiring Diagrams...
Страница 64: ...Wiring Diagrams 7 2 Part 1604858 01 E 2013 Nordson Corporation...