Description
2-2
Part 104373
−
03
E
2015 Nordson Corporation
Fluid Pressures
Pump ratio:
18.5:1
Maximum fluid output pressure:
104 bar (1500 psi)
Maximum fluid delivery:
3.8 l/min. (1.0 gal/min.)
at 60 strokes/min.
Maximum feed pressure:
1.4 bar (20 psi)
Figure 2-1 is a chart showing air input pressure to hydraulic output pressure
ratios.
1200180A
0
200 400 600 800 1000 1200 1400 1600
20
40
60
80
Hydraulic pressure (psi)
Air pressure (psi)
Figure 2-1
Air Pressure-to-Fluid Pressure Ratios
Fluid Hoses
All hoses must be Nordson or equivalent PTFE hoses with electrical
continuity between the fittings, capable of withstanding 207 bar (3000 psi)
pressure. Do not use pipe in the high pressure circuit.
Air supply hose:
1
/
2-
in. ID minimum
Hydraulic fluid hose:
1
/
4
-in. ID reinforced PTFE
Alternate tubing:
3
/
8
-in. OD x 0.035 in. wall
seamless stainless steel
Siphon hose
1
/
2
-in. ID nylon
Drain-off hose
3
/
8
-in. ID nylon