Nordson Coolwave 2 T3 Скачать руководство пользователя страница 1

Instruction Sheet

Part 1102354-02

E

 2018 Nordson Corporation

P/N 1102354-02

CoolWave

r

 2 Transformer T3 

and Wire Harness Upgrade Kit

Use the transformer and harness kit to upgrade or replace the Coolwave

r

 2

transformer.

NOTE:  

Retain the box used for shipping the T3 transformer and wiring to

comply with the conditions of warranty.

WARNING: 

 Allow only qualified personnel to perform the following tasks.

Follow the safety instructions in this document and all other related

documentation.  A qualified and competent electrician must carry out all

electrical maintenance and servicing of this equipment.

WARNING: 

 This equipment operates at high voltages up to 5000 volts dc

and is therefore potentially dangerous. The electrician servicing this

equipment must take all precautions.

WARNING: 

 Isolate the equipment at the main disconnect or lockout before

removing any of the cover panels.

T3 Transformer Versions 

See Figure 1.  Previous versions of the T3 transformer could have either

pigtail wires or Faston terminals.

NOTE:  

If transformer has Faston terminals, procedures for replacing wires

is not necessary.

Transformer with Pigtail Wires

Transformer with Faston Terminals

Faston Terminal

Figure 1

Old Versions of theTransformer

Содержание Coolwave 2 T3

Страница 1: ...t electrician must carry out all electrical maintenance and servicing of this equipment WARNING This equipment operates at high voltages up to 5000 volts dc and is therefore potentially dangerous The...

Страница 2: ...quired for replacing transformers with pigtail wires Ground Wire Primary Terminals Secondary Wires Figure 2 New Wiring Harness Upgrading the Transformer Removing Power Supply Cover 1 Remove electrical...

Страница 3: ...s with Faston terminals Tools Required S Wire cutter and stripper S Faston crimp tool S Extraction tool refer to Parts section 1 See Figure 4 Cut wires about 0 25 from the transformer winding Cut both...

Страница 4: ...rol board then the red wires at positions 1 and 7 Refer to Transformer and Harness Disposal for instructions on proper disposal Position 1 Position 7 Wire Removed from Position 7 CONN6 CONN6 Figure 5...

Страница 5: ...terminals 2 Remove the four transformer mounting screws and washers Keep hardware for installing new transformer 3 Remove transformer and refer to Transformer and Harness Disposal for instructions on...

Страница 6: ...Color and Label X1 Black X1 H Main Control Bd CONN6 1 Black CON6 1 X2 White X2 N Main Control Bd CONN6 7 White CON6 7 X3 Green Yellow X3 GND Transformer Mounting Screw Green Yellow 10 Ring Terminal Se...

Страница 7: ...iginal packaging in which it was received Failure to comply with these instructions will void the warranty Send return items to UV System Group Nordson Corporation Warranty Division 444 Gordon Ave Amh...

Страница 8: ...Transformer and Wire Harness Upgrade Kit 8 Part 1102354 02 E 2018 Nordson Corporation Issued 4 18 Original copyright date 2010 CoolWave Nordson and the Nordson logo are registered trademarks of Nords...