Power-Up and Testing
4-19
Table 4-1 SMEMA Communication Test Matrix
Action
Result
In dialog box, press
Request Board
from Upstream Tool
output button.
No. 2 LED on TS-01 comes ON.
Press TS-01 button No.
3
.
Dialog box “Board Available from
Upstream Tool” input changes to ON.
In dialog box,
press Board Available
to Downstream
output button.
No. 4 LED on TS-01 comes ON.
Press TS-01 button No.
5
.
Dialog box “Downstream Tool
Requests Board” input changes to
ON.
Figure 4-13 Conveyor I/O (Outputs 0-31)
10.
If results are not as specified, check all TS-01 connections and retest. If results are still
negative, refer to