Instruction Sheet
E
1995 Nordson Corporation
All rights reserved
108 627B
Issued 5/95
Manual 15-3
P/N 108 627B
Magnetic Dry Film Thickness Gauge
See Figure 1.
1503001A
Fig. 1 Magnetic dry film thickness gauge
The Nordson Magnetic Dry Film Thickness Gauge measures film
thickness by indicating the relative attractive force exerted on a
permanent magnet acting through non-magnetic dry coatings on a steel
substrate. The gauge is accurate to
±
5 % within ranges of 0–80 mils or
0–500 microns.
The gauge is equipped with a carrying strap and is shipped with a
protective leather carrying case.
NOTE: Make sure the film is dry. A slightly sticky film will give a
false reading.
NOTE: Surface to be measured must be free from dirt, oil, or grease.
1. Turn the gauge scale wheel to its maximum setting.
2. Place the gauge on a dry film so that the nose grommet and (if
possible) the enlarged area of the gauge body rest firmly against the
film to be measured.
1. Description
2. Operation
Smooth Steel