Instruction Sheet

E

1995 Nordson Corporation

All rights reserved

108 627B

Issued 5/95

Manual 15-3

P/N 108 627B

Magnetic Dry Film Thickness Gauge

See Figure 1.

1503001A

Fig.  1 Magnetic dry film thickness gauge

The Nordson Magnetic Dry Film Thickness Gauge measures film
thickness by indicating the relative attractive force exerted on a
permanent magnet acting through non-magnetic dry coatings on a steel
substrate.  The gauge is accurate to 

±

5 % within ranges of 0–80 mils or

0–500 microns.

The gauge is equipped with a carrying strap and is shipped with a
protective  leather carrying case.

NOTE:  Make sure the film is dry.  A slightly sticky film will give a
false reading.

NOTE:  Surface to be measured must be free from dirt, oil, or grease.

1. Turn the gauge scale wheel to its maximum setting.

2. Place the gauge on a dry film so that the nose grommet and (if

possible) the enlarged area of the gauge body rest firmly against the
film to be measured.