Program Examples
Program Example 1
Channel 1 and Channel 2:
Same control programs for both channels; all unlinked single lines with five pulses each; adjustable range = +/- 0%
(meaning that manually changing a parameter via the PICO controller menu is not possible); no external continuous
signal (ext.puls = 0); every line starts individually (with IN1 to IN9); each dispensing sequence is automatically ended
after five pulses (connected line = 0); use of different container sizes (channel 1: 1000 g; channel 2: 250 g) and thus
specification of other remaining amount limits (channel 1; 100 g; channel 2: 50 g).
[Device]
PDA2+2
[HW Revision] 2.2
[SW Revision] 2.2
[Filename]
PDA2_example_01.txt
[Description]
This is a PDA2+2 generated file.
(NOTE: Any text can be added as a comment; square brackets are not permitted.)
[Data]
Code 000000
Valve-no.
Ventil-Nr. 1
container
limit
adjustable range
temperature
stop
Gebinde, voll Grenzrestmenge
Einstellbereich
Temperatur
Stop
Delay-Time
1000.00
100.00
0
35.0
1
0.00
line
dosing time
pausetime
number of runs IN
connected line connecting time blocknumber dosing value ext.puls
eZeile
Dosierzeit
Pausenzeit
Pulsanzahl
IN
V-Zeile
Verz.-Zeit
Blockanzahl Menge ext.Dauers.
1
0.05
10.00
5
1 0
0
1
0.05
0
2
0.10
10.00
5
2 0
0
1
0.10
0
3
0.20
10.00
5
3 0
0
1
0.20
0
4
0.40
10.00
5
4 0
0
1
0.40
0
5
0.80
10.00
5
5 0
0
1
0.80
0
6
1.60
10.00
5
6 0
0
1
1.60
0
7
3.20
10.00
5
7 0
0
1
3.20
0
8
6.40
10.00
5
8 0
0
1
6.40
0
9
12.80
10.00
5
9 0
0
1
12.80
0
Valve-no.
Ventil-Nr. 2
container
limit
adjustable range
temperature
stop
Gebinde, voll Grenzrestmenge
Einstellbereich
Temperatur
Stop
Delay-Time
250.00
50.00
0
35.0
1
0.00
line
dosing time
pausetime
number of runs IN
connected line connecting time blocknumber dosing value ext.puls
Zeile
Dosierzeit
Pausenzeit
Pulsanzahl
IN
V-Zeile
Verz.-Zeit
Blockanzahl Menge ext.Dauers.
1
0.05
10.00
5
1 0
0
1
0.05
0
2
0.10
10.00
5
2 0
0
1
0.10
0
3
0.20
10.00
5
3 0
0
1
0.20
0
4
0.40
10.00
5
4 0
0
1
0.40
0
5
0.80
10.00
5
5 0
0
1
0.80
0
6
1.60
10.00
5
6 0
0
1
1.60
0
7
3.20
10.00
5
7 0
0
1
3.20
0
8
6.40
10.00
5
8 0
0
1
6.40
0
9
12.80
10.00
5
9 0
0
1
12.80
0
[Data End]
PICO Controller 2+2-XCH-V2
37
www.nordsonefd.com [email protected]