Parameters and Value Ranges
This table includes the parameters accessible via the PICO controller menu and the parameters that can be set via a
TXT file/control program. Refer to “Control Programs” on page 38 for detailed information on control programs.
PICO Controller
Menu Parameter
Selection
Control Program/TXT
File Parameter Name
(Case-Sensitive)
Value Range
Explanation
Container
container
0–9999.99 (g)
Total material quantity in a full container (this
quantity from a full container is available for
dispensing)
Limit
limit
0–9999.99 (g)
When the material in the container falls to this
level, a signal is emitted to allow the required
action to be taken in time (e.g., container change)
NOTE:
The value shown for Remaining is equal to
the amount specified for the full container minus
amount used.
Not available
adjustable range
0–100 (%)
or
v = full range
Specification of the possible adjustment in percent
of the dispensing time, pause time, or number of
pulses. The adjustable range allows the entire (full)
range of values for the variation.
Temperature
temperature
0–100 (°C)
or
0-200 (°C)
Specification of the dispensing material
temperature in the dispensing valve; the value
applies to all of the dispensing sequences in the
channel
NOTE:
To set a temperature higher than 100 °C,
you must change the temperature setting range.
Refer to “Changing the Temperature Setting
Range” on page 45.
Stop
stop
0 = Off
1 = On
2 = Emergency off
The EMERGENCY OFF feature is activated by
disrupting the 24 V signal to pin 15. The action
taken when the signal is disrupted depends on
the value selected (0, 1, or 2). The values have the
following meanings:
0 = Off/not active
1 = On (current pulse output is completely
executed)
2 = Emergency off (current pulse output is
canceled as quickly as possible) executed
Not available
Delay-time
0–9999.99 (ms) resolution
10 bit
Maximum value of a variable pause time; the
duration of the pause is changed proportionally
to the analog input voltage 0 to 10 V within the
range of 0.12 ms to delay time (0V = 0.12 ms; 10V
= delay time)
Row
line
1–99
Ascending numbering of the program lines; 1 to 99
lines can be saved per channel.
Pulse time
dosing time
0 (ms)
or
0.05–9999.99 (ms)
Duration of a dispensing pulse—material is
metered during this time; 0.05 ms minimum
dispensing time for a dispensing valve; 0 ms if
dispensing sequence is to begin with a pause
Continued on next page
PICO Controller 2+2-XCH-V3
32