34
Maintenance and Service
DJ-9520 Heat Exchanger Version
a.
With the cam lever down to the open position, thread in the four (4) socket head cap
screws.
b.
Attach the Valve Body Alignment Tool (P/N 7214835) to the Junction Box and Collar
and tighten the adjustment knob hand tight.
Figure 6-35 Junction Box to Valve Body Alignment
WARNING!
Failure to use the Valve Body Alignment Tool may cause leakage, poor Heat
Exchanger performance, damage to the chamber, or poor dispense quality.
c.
With the cam lever down to the open position, tighten the four (4) socket head cap screws
with a 2.5 mm hex wrench.
d.
Remove the Junction Box to Valve Body Alignment Tool.
8.
Reassemble the Fluid Chamber, Seat, Nozzle, and TCA. See