65
7.4
Removing and installing components for maintenance
7.4.1 Preparing the Nordmann Omega for the removal of components
Before starting any removal work set the Nordmann Omega out of operation and drain the steam tank.
Please refer to the notes in
7.4.2 Removal and installation of the steam tank
WARNING!
Danger of burning!
Before removal of the steam tank ensure the steam tank is empty and has cooled down, that no more
burning danger exists.
DANGER!
Danger of electric hazard!
You may get in touch with live parts when the steam generator is open. Touching live parts
may cause severe injury or even lethal violation.
Prevention
: Before removal of the steam tank make sure the steam generator is separated from the
mains (switch off electrical isolator in the mains supply line and check tensionless state with a voltage
tester).
1. Loosen the retaining screw on the unit cover using a screwdriver, then remove the unit cover.
2. Free the hose clamp on the steam outlet connector using a screwdriver and remove steam hose
from the steam connector. Release hose clamp of the pressure equalizing hose on top of the steam
tank and remove hose from the connector. Unplug all heating cables from their sockets. Remove
connecting cables from overtemperature switch(es).
1
2
Содержание Omega 12
Страница 1: ...OPERATION MANUAL Steam generator Nordmann Omega 2590562 D EN 1901 ...