46
LIBERO LINE FRY TOP INDUCTION
4.5.3.4 S3,
SELF-DIAGNOSTIC
TEST
WITH
GENERATORS
ON
Service Utility S3:
Power boards (POW) self-diagnostic test with induction generators ON.
During this test pots must be present on all cooking zones (For FRYTOP: cooking plate must be mounted over
the coils). Induction generators are ON (APD relay closed). Pot detection is executed. All generators (meaning
all coils) on all cooking zones are ON at maximum power defined in the configuration (Level 9).
NOTE:
This test is not always accurate. By repeating the test several times, it happens with a certain frequency
that the equipment is unable to provide the result without a physical change having occurred on the equipment.
On double zone appliances, most of the time only the result of POW1 (Zone 1, left digit) is showed whereas
right digit stays off. Other times the result for POW2 appears after about 2 seconds.
Содержание 406600899
Страница 1: ...Service Manual Fry Induction Top IGEC 3P 2ZQT Art 406600899 2021 04 ...
Страница 13: ...13 LIBERO LINE FRY TOP INDUCTION DOUBLE ZONE ...
Страница 21: ...21 LIBERO LINE FRY TOP INDUCTION In case of need the supply cable can be replaced removed ...
Страница 44: ...44 LIBERO LINE FRY TOP INDUCTION ...
Страница 45: ...45 LIBERO LINE FRY TOP INDUCTION ...
Страница 47: ...47 LIBERO LINE FRY TOP INDUCTION ...
Страница 48: ...48 LIBERO LINE FRY TOP INDUCTION ...
Страница 50: ...50 LIBERO LINE FRY TOP INDUCTION ...
Страница 51: ...51 LIBERO LINE FRY TOP INDUCTION ...
Страница 54: ...54 LIBERO LINE FRY TOP INDUCTION ...
Страница 56: ...56 LIBERO LINE FRY TOP INDUCTION ...
Страница 64: ...64 LIBERO LINE FRY TOP INDUCTION 6 2 2 2 VENTILATOR 6 2 2 3 FILTER Refer to pictures at FILTER ...